992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 73–96 of 992

EVAPCO AT 112-3N20 cooling tower

Cooling tower — 3058 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 71.4 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-3O18 cooling tower

Cooling tower — 3172 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 74.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-3O20 cooling tower

Cooling tower — 3317 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 76.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4I12 cooling tower

Cooling tower — 1477 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 32.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4I14 cooling tower

Cooling tower — 1621 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 35.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4J12 cooling tower

Cooling tower — 1696 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4J14 cooling tower

Cooling tower — 1871 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 40.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4J18 cooling tower

Cooling tower — 2270 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 50.4 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4K12 cooling tower

Cooling tower — 1849 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 40.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4K14 cooling tower

Cooling tower — 2015 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 44.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4K18 cooling tower

Cooling tower — 2506 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 55.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4K20 cooling tower

Cooling tower — 2506 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 56.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4L12 cooling tower

Cooling tower — 1989 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 43.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4L14 cooling tower

Cooling tower — 2164 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 47.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4L18 cooling tower

Cooling tower — 2655 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 59.2 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4L20 cooling tower

Cooling tower — 2708 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 60.6 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4M12 cooling tower

Cooling tower — 2107 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 46.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4M14 cooling tower

Cooling tower — 2296 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 50.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4M18 cooling tower

Cooling tower — 2813 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 62.7 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4M20 cooling tower

Cooling tower — 2870 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 64.2 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4N12 cooling tower

Cooling tower — 2256 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 50.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4N14 cooling tower

Cooling tower — 2515 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 55.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 112-4N18 cooling tower

Cooling tower — 3089 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 68.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 112-4N20 cooling tower

Cooling tower — 3190 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 70.2 m³/s of air.

catalog
Cooling tower
‹ Previous123456…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.