992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 817–840 of 992

EVAPCO AT 312-3K60 cooling tower

Cooling tower — 7010 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 171.6 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3L36 cooling tower

Cooling tower — 5766 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 134.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3L42 cooling tower

Cooling tower — 6257 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 146.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3L54 cooling tower

Cooling tower — 7676 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 180.4 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3L60 cooling tower

Cooling tower — 7646 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 184.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3M36 cooling tower

Cooling tower — 6125 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 142.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3M42 cooling tower

Cooling tower — 6655 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 154.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3M54 cooling tower

Cooling tower — 8110 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 191.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3M60 cooling tower

Cooling tower — 8145 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 194.9 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3N42 cooling tower

Cooling tower — 7282 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 169.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3N54 cooling tower

Cooling tower — 8920 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 209.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3N60 cooling tower

Cooling tower — 9126 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 213.0 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3O54 cooling tower

Cooling tower — 9560 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 224.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3O60 cooling tower

Cooling tower — 9902 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 228.4 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4I36 cooling tower

Cooling tower — 4473 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 99.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4I42 cooling tower

Cooling tower — 4920 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 107.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4J36 cooling tower

Cooling tower — 5144 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 112.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4J42 cooling tower

Cooling tower — 5665 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 122.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4J54 cooling tower

Cooling tower — 6835 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 151.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4K36 cooling tower

Cooling tower — 5595 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 123.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4K42 cooling tower

Cooling tower — 6112 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 134.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4K54 cooling tower

Cooling tower — 7558 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 165.4 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4K60 cooling tower

Cooling tower — 7479 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 168.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4L36 cooling tower

Cooling tower — 6024 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 132.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…3334353637…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.