992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 793–816 of 992

EVAPCO AT 312-2J54 cooling tower

Cooling tower — 5801 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 156.0 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2K36 cooling tower

Cooling tower — 4846 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 127.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-2K42 cooling tower

Cooling tower — 5236 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 138.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-2K54 cooling tower

Cooling tower — 6568 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 170.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2K60 cooling tower

Cooling tower — 5994 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 174.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2L36 cooling tower

Cooling tower — 5201 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 136.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-2L42 cooling tower

Cooling tower — 5648 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 148.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-2L54 cooling tower

Cooling tower — 6949 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 183.6 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2L60 cooling tower

Cooling tower — 6607 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 187.3 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2M36 cooling tower

Cooling tower — 5507 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 145.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-2M42 cooling tower

Cooling tower — 5985 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 157.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-2M54 cooling tower

Cooling tower — 7317 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 194.6 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2M60 cooling tower

Cooling tower — 7107 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 198.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2N54 cooling tower

Cooling tower — 8062 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 213.2 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2N60 cooling tower

Cooling tower — 8171 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 217.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-2O60 cooling tower

Cooling tower — 8864 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 233.0 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3I36 cooling tower

Cooling tower — 4206 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 100.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3I42 cooling tower

Cooling tower — 4579 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 109.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3J36 cooling tower

Cooling tower — 4916 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 114.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3J42 cooling tower

Cooling tower — 5385 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 124.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3J54 cooling tower

Cooling tower — 6454 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 153.7 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-3K36 cooling tower

Cooling tower — 5363 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 125.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3K42 cooling tower

Cooling tower — 5827 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 136.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-3K54 cooling tower

Cooling tower — 7221 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 168.1 m³/s of air.

catalog
Cooling tower
‹ Previous1…3233343536…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.