992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 841–864 of 992

EVAPCO AT 312-4L42 cooling tower

Cooling tower — 6550 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 143.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4L54 cooling tower

Cooling tower — 8009 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 177.6 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4L60 cooling tower

Cooling tower — 8079 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 181.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4M36 cooling tower

Cooling tower — 6388 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 139.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4M42 cooling tower

Cooling tower — 6962 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 152.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4M54 cooling tower

Cooling tower — 8478 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 188.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4M60 cooling tower

Cooling tower — 8566 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 191.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4N36 cooling tower

Cooling tower — 6835 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 153.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4N42 cooling tower

Cooling tower — 7615 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 166.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 312-4N54 cooling tower

Cooling tower — 9306 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 205.7 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4N60 cooling tower

Cooling tower — 9525 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 209.7 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4O54 cooling tower

Cooling tower — 9994 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 220.4 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4O60 cooling tower

Cooling tower — 10305 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 224.7 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4P54 cooling tower

Cooling tower — 10371 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 233.5 m³/s of air.

catalog
Cooling tower

EVAPCO AT 312-4P60 cooling tower

Cooling tower — 10691 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 238.1 m³/s of air.

catalog
Cooling tower

EVAPCO AT 314-2K72 cooling tower

Cooling tower — 7838 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 220.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-2L72 cooling tower

Cooling tower — 8701 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 236.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-2M72 cooling tower

Cooling tower — 9179 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 250.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-2N72 cooling tower

Cooling tower — 9950 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 275.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-2O72 cooling tower

Cooling tower — 10686 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 295.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-3K72 cooling tower

Cooling tower — 9008 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 217.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-3L72 cooling tower

Cooling tower — 9889 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 232.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-3M72 cooling tower

Cooling tower — 10358 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 246.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 314-3N72 cooling tower

Cooling tower — 11396 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 270.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…3435363738…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.