Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 193–216 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Grundfos MAGNA3 50-80 F (N) circulator CatalogPumpsGrundfosPump rated 4.10 kg/s at 0.17 kW.NA, EUOpen in the builder
VEAB VFLPG-800-400-25 kW-3x400V (800×400 rectangular duct heater) CatalogHeatersVEABAir heater, 25.0 kW at 0.64 m³/s.EUOpen in the builder
Sigma SRK-P-5-CV2-F6 panel radiator (pedestal, CV2-F6 coil), per foot CatalogRadiators and emittersSigmaHydronic emitter rated per foot of active length: 0.207 kW at an excess of 52.8 K, exponent 1.3.NAOpen in the builder
PURE Humidifier ES-66 electric steam humidifier (198 lb/h, 66 kW) CatalogHumidifiersPURE HumidifierSteam humidifier, 89.8 kg/h of steam on 66.0 kW of electricity.NAOpen in the builder
Embraco EGM80CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.66 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
DRI HRW-1900-MS 270A (N) total energy recovery wheel Catalog AHRI 1060 (air-to-air energy recovery component)Recovery coresDRISensible-and-latent recovery core, 1.293 m² face a stream, 2.59 / 2.59 m³/s.NAOpen in the builder
Carnes VGBA 12 belt-drive forward-curved duct blower (12.5 in. wheel, 1430 rpm, 3 HP) CatalogFansCarnesFan rated 1.23 m³/s at 1.58 kW.NAOpen in the builder
KSB Etaline L 032-032-080 in-line pump, 2900 rpm CatalogPumpsKSBPump rated 1.55 kg/s at 0.28 kW.EUOpen in the builder
Cambridge Air Solutions S1850 direct gas-fired space heater, 7½ HP (1,850 MBH input at a 140 °F rise) CatalogHeatersCambridge Air SolutionsAir heater, 498.8 kW at 4.82 m³/s.NAOpen in the builder
Sigma SRK-P-5-CV3-2H-4CC panel radiator (pedestal, CV3-2H-4CC coil), per foot CatalogRadiators and emittersSigmaHydronic emitter rated per foot of active length: 0.468 kW at an excess of 52.8 K, exponent 1.3.NAOpen in the builder
PURE Humidifier ES-7.5 electric steam humidifier (22.5 lb/h, 7.5 kW) CatalogHumidifiersPURE HumidifierSteam humidifier, 10.2 kg/h of steam on 7.5 kW of electricity.NAOpen in the builder
Invotech YSF100A1G-V100 (R22 low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 11.3 kW cooling, 6.10 kW input, COP 1.85 at -30/35 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
DRI HRW-2000-MS 200 (N) total energy recovery wheel Catalog AHRI 1060 (air-to-air energy recovery component)Recovery coresDRISensible-and-latent recovery core, 1.439 m² face a stream, 2.88 / 2.88 m³/s.NAOpen in the builder
Chicago Blower Design 51 airfoil plenum fan, size 182 (3548 rpm; 20 HP motor assumed) CatalogFansChicago BlowerFan rated 2.83 m³/s at 12.15 kW.NAOpen in the builder
Grundfos TP 100-1400/2 in-line pump, 2-pole CatalogPumpsGrundfosPump rated 39.33 kg/s at 75.55 kW.EUOpen in the builder
King KFUH2008-3-2S3-ECM electric unit heater (8 kW, 208 V 3-phase) CatalogHeatersKing ElectricAir heater, 8.0 kW at 0.43 m³/s.NAOpen in the builder
Sigma SRK-P-5-CV3-3H-4CC panel radiator (pedestal, CV3-3H-4CC coil), per foot CatalogRadiators and emittersSigmaHydronic emitter rated per foot of active length: 0.550 kW at an excess of 52.8 K, exponent 1.3.NAOpen in the builder
PURE Humidifier ES-78 electric steam humidifier (234 lb/h, 78 kW) CatalogHumidifiersPURE HumidifierSteam humidifier, 106.1 kg/h of steam on 78.0 kW of electricity.NAOpen in the builder
Mitsubishi Electric SBB172FABMC (R134a inverter rotary) CatalogCompressorsMitsubishi ElectricR134a compressor — 5.1 kW cooling, 1.51 kW input, COP 3.36 at the AHRI 7.2/54.4 °C rating point.Open in the builder
DRI HRW-2000-MS 270A (N) total energy recovery wheel Catalog AHRI 1060 (air-to-air energy recovery component)Recovery coresDRISensible-and-latent recovery core, 1.439 m² face a stream, 2.88 / 2.88 m³/s.NAOpen in the builder
Greenheck GB-100HP belt-drive high-pressure centrifugal roof downblast exhaust fan (2550 rpm, 1/2 HP) CatalogFansGreenheckFan rated 0.30 m³/s at 0.48 kW.NAOpen in the builder
KSB Etaline L 032-032-100 in-line pump, 2900 rpm CatalogPumpsKSBPump rated 1.96 kg/s at 0.32 kW.EUOpen in the builder
Powrmatic CPx 175 gas cabinet heater (175 kW output) CatalogHeatersPowrmaticAir heater, 175.0 kW at 3.36 m³/s.EUOpen in the builder
Sigma SRK-P-5-CV3-4H-3CC panel radiator (pedestal, CV3-4H-3CC coil), per foot CatalogRadiators and emittersSigmaHydronic emitter rated per foot of active length: 0.556 kW at an excess of 52.8 K, exponent 1.3.NAOpen in the builder
‹ Previous1…7891011…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one