Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 1,537–1,560 of 3,474

NameCompanyCategoryCapacityMarketsOpen in the builder
EVAPCO AT 212-3H9 cooling tower (276 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 212-3H9 — an AT cooling tower, 276 nominal tons (1214 kW): rated to cool 831 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection910–1517 kWEUOpen in the builder
Baltimore Aircoil PCC-0441-1218N020 evaporative condenser (2.7 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0441-1218N020 — a PCC evaporative condenser rejecting 2679 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 49.2 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2009–3348 kWEUOpen in the builder
EVAPCO ATWB 9-3J8 closed-circuit cooler (112 tons, 492 kW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 9-3J8 — an ATWB closed-circuit cooler, 112 nominal tons (492 kW): rated to cool 281 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 19.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection369–614 kWEUOpen in the builder
Baltimore Aircoil PFI-0718N-4D2ES-M2 closed-circuit cooler (190 tons, 837 kW) — modelled Example modelled from published data
BAC's PFI-0718N-4D2ES-M2 — a PFi closed-circuit cooler, 190 nominal tons (837 kW): rated to cool 573 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 42.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection628–1046 kWEUOpen in the builder
EVAPCO AT 212-3I28 cooling tower (685 tons, 3.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 212-3I28 — an AT cooling tower, 685 nominal tons (3010 kW): rated to cool 2061 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 72.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2258–3763 kWEUOpen in the builder
Baltimore Aircoil Series 1500 S15E-1218-10LC cooling tower (598 tons, 2.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S15E-1218-10LC — a Series 1500 cooling tower, 598 nominal tons (2629 kW): rated to cool 1800 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 64.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1972–3286 kWEUOpen in the builder
EVAPCO ATWB 9-3K11 closed-circuit cooler (158 tons, 695 kW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 9-3K11 — an ATWB closed-circuit cooler, 158 nominal tons (695 kW): rated to cool 396 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 26.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection521–868 kWEUOpen in the builder
Baltimore Aircoil Series 3000 S3E-1222-14P cooling tower (869 tons, 3.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S3E-1222-14P — a Series 3000 cooling tower, 869 nominal tons (3821 kW): rated to cool 2616 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 96.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2865–4776 kWEUOpen in the builder
EVAPCO AT 212-3I9 cooling tower (301 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 212-3I9 — an AT cooling tower, 301 nominal tons (1323 kW): rated to cool 906 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 30.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection992–1654 kWEUOpen in the builder
Baltimore Aircoil Series V VT1-M371-P cooling tower (370 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓
BAC's VT1-M371-P — a Series V cooling tower, 370 nominal tons (1625 kW): rated to cool 1113 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 33.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1219–2032 kWEUOpen in the builder
EVAPCO ATWB 9-3K14 closed-circuit cooler (209 tons, 921 kW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 9-3K14 — an ATWB closed-circuit cooler, 209 nominal tons (921 kW): rated to cool 525 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 32.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection690–1151 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-096-41Q closed-circuit cooler (109 tons, 478 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓
BAC's VF1-096-41Q — a Series V closed circuit closed-circuit cooler, 109 nominal tons (478 kW): rated to cool 327 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 29.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection358–597 kWEUOpen in the builder
EVAPCO AT 212-3J24 cooling tower (738 tons, 3.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 212-3J24 — an AT cooling tower, 738 nominal tons (3242 kW): rated to cool 2220 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 75.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2432–4053 kWEUOpen in the builder
Baltimore Aircoil VCA-302A evaporative condenser (1.3 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-302A — a VCA evaporative condenser rejecting 1301 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 23.8 m³/s of the maker's own printed air, with a 4.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection976–1626 kWEUOpen in the builder
EVAPCO ATWB 9-3K18 closed-circuit cooler (333 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 9-3K18 — an ATWB closed-circuit cooler, 333 nominal tons (1464 kW): rated to cool 835 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 47.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1098–1830 kWEUOpen in the builder
Baltimore Aircoil VRC-0442B-1218N-KA evaporative condenser (2.7 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0442B-1218N-KA — a Vertex VRC evaporative condenser rejecting 2684 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 53.3 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2013–3355 kWEUOpen in the builder
EVAPCO AT 212-3J28 cooling tower (807 tons, 3.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 212-3J28 — an AT cooling tower, 807 nominal tons (3549 kW): rated to cool 2430 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 82.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2662–4436 kWEUOpen in the builder
Baltimore Aircoil CXVB-327-0818-15 evaporative condenser (2.0 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVB-327-0818-15 — a CXVB evaporative condenser rejecting 1981 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 40.2 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1486–2476 kWEUOpen in the builder
EVAPCO ATWB 9-3K21 closed-circuit cooler (383 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 9-3K21 — an ATWB closed-circuit cooler, 383 nominal tons (1685 kW): rated to cool 962 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 53.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1264–2107 kWEUOpen in the builder
Baltimore Aircoil FXV-0818B-32Q-O closed-circuit cooler (288 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓
BAC's FXV-0818B-32Q-O — an FXV closed-circuit cooler, 288 nominal tons (1266 kW): rated to cool 867 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 58.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection950–1583 kWEUOpen in the builder
EVAPCO AT 212-3J36 cooling tower (974 tons, 4.3 MW) — modelled Example modelled from published data
EVAPCO's 212-3J36 — an AT cooling tower, 974 nominal tons (4281 kW): rated to cool 2931 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 102.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection3210–5351 kWEUOpen in the builder
Baltimore Aircoil PCC-0466-1024N030 evaporative condenser (2.8 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0466-1024N030 — a PCC evaporative condenser rejecting 2831 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 61.7 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2123–3538 kWEUOpen in the builder
EVAPCO ATWB 9-3L14 closed-circuit cooler (226 tons, 992 kW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 9-3L14 — an ATWB closed-circuit cooler, 226 nominal tons (992 kW): rated to cool 566 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 35.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection744–1240 kWEUOpen in the builder
Baltimore Aircoil PFI-0718N-4D3DS-K2 closed-circuit cooler (153 tons, 675 kW) — modelled Example modelled from published data
BAC's PFI-0718N-4D3DS-K2 — a PFi closed-circuit cooler, 153 nominal tons (675 kW): rated to cool 462 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 33.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection506–843 kWEUOpen in the builder
‹ Previous1…6364656667…145Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers