4,679 listings in HVAC Builder's catalog from Danfoss' published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Danfoss has not claimed it.

Compressor maps by refrigerant: R410A 625, R22 557, R404A 467, R407C 432, R134a 400, R452A 270, R454B 253, R449A 251, R448A 250, R513A 225, R407A 196, R407F 196, R454C 152, R455A 152, R454A 93, R452B 82, R32 69, R1234ze(E) 8, R245fa 1.

Danfoss compressor ranges

Each range on a page of its own: every model code with its refrigerants, frequencies and ratings, and every model a page.

Are you Danfoss?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Components

Showing 601–624 of 4,679

NameTypeRatingOpen in the builder
Danfoss DSF155-4 (R32 scroll, 50 Hz, HT) CatalogCompressorsR32 compressor — 34.2 kW cooling, 11.60 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss DSH105-4 (R452B scroll, 60 Hz, A/C) CatalogCompressorsR452B compressor — 31.9 kW cooling, 9.64 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HCJ121T4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsR410A compressor — 29.7 kW cooling, 9.22 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HLH061T7A (R410A scroll, 60 Hz) CatalogCompressorsR410A compressor — 18.1 kW cooling, 5.73 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HLJ072T7A (R454B scroll, 60 Hz) CatalogCompressorsR454B compressor — 20.2 kW cooling, 6.24 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HLM078T4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsR22 compressor — 23.0 kW cooling, 6.70 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HLP081T2 (R407C scroll, 50 Hz, A/C) CatalogCompressorsR407C compressor — 19.9 kW cooling, 6.16 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HRH031U5 (R410A scroll, 50 Hz, A/C) CatalogCompressorsR410A compressor — 7.7 kW cooling, 2.67 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HRM038U1 (R22 scroll, 60 Hz, A/C) CatalogCompressorsR22 compressor — 11.1 kW cooling, 3.39 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss HRP040T4 (R407C scroll, 60 Hz, A/C) CatalogCompressorsR407C compressor — 11.0 kW cooling, 3.70 kW input, COP 2.97 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss LLZ013T2C (R454C scroll, 60 Hz) CatalogCompressorsR454C compressor — 3.5 kW cooling, 2.00 kW input, COP 1.77 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Danfoss MLM045T4 (R22 scroll, 50 Hz, MT) CatalogCompressorsR22 compressor — 16.5 kW cooling, 5.13 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss MLZ015T1C (R455A scroll, 60 Hz) CatalogCompressorsR455A compressor — 6.4 kW cooling, 2.39 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss MT028-5 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsR22 compressor — 7.4 kW cooling, 2.55 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss MTZ018-3 (R454C hermetic reciprocating, 60 Hz) CatalogCompressorsR454C compressor — 4.0 kW cooling, 1.65 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss NTZ048-9B (R404A hermetic reciprocating, 60 Hz, LT) CatalogCompressorsR404A compressor — 0.61 kW cooling, 0.71 kW input, COP 0.87 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Danfoss PSH023-3E (R454B scroll, 60 Hz) CatalogCompressorsR454B compressor — 29.5 kW cooling, 9.91 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss SH140-3 (R410A scroll, 60 Hz, A/C) CatalogCompressorsR410A compressor — 42.3 kW cooling, 12.94 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss SM115-3 (R22 scroll, 60 Hz, A/C) CatalogCompressorsR22 compressor — 33.7 kW cooling, 10.08 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss SZ100-3 (R407C scroll, 60 Hz, A/C) CatalogCompressorsR407C compressor — 26.5 kW cooling, 8.18 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss VLZ065TGD (R449A inverter scroll) CatalogCompressorsR449A compressor — 23.2 kW cooling, 9.06 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss VZH035CHANA (R410A inverter scroll, A/C) CatalogCompressorsR410A compressor — 18.5 kW cooling, 6.40 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss DCJ106T2A (R410A scroll, 50 Hz) CatalogCompressorsR410A compressor — 22.9 kW cooling, 8.15 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss DSF155-4 (R32 scroll, 60 Hz, HT) CatalogCompressorsR32 compressor — 45.2 kW cooling, 13.82 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…2425262728…195Next ›

How the model reads against Danfoss' data

Danfoss compressor maps converted from the maker's own selection database4 677 maps (186 variable-speed with a step per rated speed, 4 427 with a mass-flow set); 553 nomenclature maps; 400 coefficients against the reportthe VZH052's 400 coefficients identical to the report's; eighteen family medians between 0.95 and 1.053 of their model number, 543 of the 553 within 10 % (the ten outside are the smallest Maneurop recips, whose numbers are size codes); the closure median on every family between 0.994 and 1.049 (the R407C scrolls at the top, about 5 % over; nearly every other family within 1 %) over 4 427 sets, the three sets that disagree withheld, and the thirteen HHP heat-pump maps left out because their capacity set is a heating capacity (their closure reads 0.73–0.78, and ṁ·Δh + P reproduces it to 3 %); the polynomials substituted exactly, never refitted
Part-load interpolation between published compressor stepsthe envelope between 16 steps0.04 % mean, 0.21 % worst between the knots
A data centre's cooling loop as a heat source: the water-source heat pump against the same machine on aira full Seattle year and one winter week, both sourcesthe same 55.2 MWh into the radiators either way; 7.6 MWh of electricity on the loop against 17.9 on air (seasonal COP 7.3 against 3.1 — the inverter's published steps are what the loop-source machine spends most of the year on, at part speed near its best point), and the chiller 51.2 against 56.2 MWh for the 48.5 MWh the heat pump took off the loop — the site 100.5 against 115.8 MWh, 13 % (re-read on 3 Oct 2026: the chiller now holds its envelope's lowest condensing temperature in mild weather, where it had read an extrapolated COP, and the site saving was 15 %). The ring conserves within 2 % (CRAH duty = heat pump take + chiller duty) with the one-hour lag, both plants converge every hour, and the north floor is held to 8 unmet hours where the air-source machine leaves it 15. Before the high-pressure cutout (the row below) the air-source variant failed 705 hours a year. What the guard cannot say: the paper reports no seasonal COP and no per-kilowatt figure, so the machine is the catalog map on both sides and only the arrangement is the anchor. (Until 4 Sep 2026 the plant was a Copeland ZP91KCE run as a flat-scaling inverter emulation and read 9.9 against 19.2 MWh, COP 5.6 / 2.9, the site 12 % down.)
A maker's inverter scroll read from its own selector: the Danfoss VZH052CJeighteen speeds; three selector readings at te −10 / tc 30 (1 002, 3 000, 6 000 rpm); four envelope points for the displacement; the rating point and a grid for the cycle closurecapacity and power at each of the three speeds within 0.3 % of the selector's own rows; the three parameter sets close the refrigeration cycle within 0.5 % at the rating point and 3 % across the grid, each step's own sets within 1 %; the implied volumetric efficiency sits inside the scroll band at every envelope point (the same band the VZH088 entry is held to). The map carries the maker's 65 °C condensing ceiling as a polygon, which is what the cutout rule below reads

From the validation page; every row is held by a test.

Worked cases that run Danfoss machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.