992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 265–288 of 992

EVAPCO AT 19-4I12 cooling tower

Cooling tower — 1174 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 25.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4I14 cooling tower

Cooling tower — 1293 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 28.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4I6 cooling tower

Cooling tower — 688 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 15.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4I8 cooling tower

Cooling tower — 819 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 17.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4I9 cooling tower

Cooling tower — 916 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 20.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4J11 cooling tower

Cooling tower — 1183 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 26.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4J12 cooling tower

Cooling tower — 1310 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 28.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4J14 cooling tower

Cooling tower — 1441 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 31.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4J6 cooling tower

Cooling tower — 749 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 17.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4J8 cooling tower

Cooling tower — 907 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 20.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4J9 cooling tower

Cooling tower — 1060 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 23.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4K11 cooling tower

Cooling tower — 1306 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 28.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4K12 cooling tower

Cooling tower — 1446 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 31.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4K14 cooling tower

Cooling tower — 1582 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4K9 cooling tower

Cooling tower — 1161 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 25.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4L11 cooling tower

Cooling tower — 1376 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4L12 cooling tower

Cooling tower — 1542 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4L14 cooling tower

Cooling tower — 1713 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4M12 cooling tower

Cooling tower — 1590 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 35.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 19-4M14 cooling tower

Cooling tower — 1810 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 39.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-2I24 cooling tower

Cooling tower — 1994 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 61.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-2I36 cooling tower

Cooling tower — 2541 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 81.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-2J24 cooling tower

Cooling tower — 2423 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 69.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-2J36 cooling tower

Cooling tower — 3071 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 92.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…1011121314…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.