992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 313–336 of 992

EVAPCO AT 210-4L36 cooling tower

Cooling tower — 4324 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 105.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-4M24 cooling tower

Cooling tower — 3439 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 83.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-4M36 cooling tower

Cooling tower — 4574 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 111.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-4N24 cooling tower

Cooling tower — 3593 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 87.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 210-4N36 cooling tower

Cooling tower — 4995 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 121.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2F9 cooling tower

Cooling tower — 784 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 21.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2G9 cooling tower

Cooling tower — 986 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 25.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2H9 cooling tower

Cooling tower — 1082 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 28.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2I24 cooling tower

Cooling tower — 2454 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 67.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2I28 cooling tower

Cooling tower — 2620 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 73.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2J24 cooling tower

Cooling tower — 2922 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 76.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2J28 cooling tower

Cooling tower — 3141 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 83.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2J36 cooling tower

Cooling tower — 3842 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 103.9 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-2K24 cooling tower

Cooling tower — 3194 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 84.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2K28 cooling tower

Cooling tower — 3448 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 91.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2K36 cooling tower

Cooling tower — 4355 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 113.8 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-2K40 cooling tower

Cooling tower — 4022 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 116.3 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-2L24 cooling tower

Cooling tower — 3426 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 90.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2L28 cooling tower

Cooling tower — 3724 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 98.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2L36 cooling tower

Cooling tower — 4605 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 122.3 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-2L40 cooling tower

Cooling tower — 4438 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 124.9 m³/s of air.

catalog
Cooling tower

EVAPCO AT 212-2M24 cooling tower

Cooling tower — 3628 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 95.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2M28 cooling tower

Cooling tower — 3943 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 104.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 212-2M36 cooling tower

Cooling tower — 4850 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 129.6 m³/s of air.

catalog
Cooling tower
‹ Previous1…1213141516…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.