EVAPCO Unclaimed

992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 697–720 of 992

EVAPCO AT 27-4L28 cooling tower

Cooling tower — 2559 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 68.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 27-4M28 cooling tower

Cooling tower — 2892 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 72.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-2F17 cooling tower

Cooling tower — 951 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 25.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-2G17 cooling tower

Cooling tower — 1200 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 29.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-2H17 cooling tower

Cooling tower — 1301 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-2I17 cooling tower

Cooling tower — 1398 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-3F17 cooling tower

Cooling tower — 1082 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 24.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-3G17 cooling tower

Cooling tower — 1332 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 29.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-3H17 cooling tower

Cooling tower — 1450 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-3I17 cooling tower

Cooling tower — 1569 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 36.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-3J17 cooling tower

Cooling tower — 1722 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 41.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-4F17 cooling tower

Cooling tower — 1170 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 24.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-4G17 cooling tower

Cooling tower — 1398 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 28.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-4H17 cooling tower

Cooling tower — 1516 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 32.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-4I17 cooling tower

Cooling tower — 1634 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 35.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 28-4J17 cooling tower

Cooling tower — 1814 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 40.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2G18 cooling tower

Cooling tower — 1200 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2G21 cooling tower

Cooling tower — 1380 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 38.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2H18 cooling tower

Cooling tower — 1441 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 38.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2H21 cooling tower

Cooling tower — 1661 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 43.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2H24 cooling tower

Cooling tower — 1753 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 47.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2H28 cooling tower

Cooling tower — 1954 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 53.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2I18 cooling tower

Cooling tower — 1586 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 42.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2I21 cooling tower

Cooling tower — 1788 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 47.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…2829303132…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.