992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 721–744 of 992

EVAPCO AT 29-2I24 cooling tower

Cooling tower — 1989 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 51.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2I28 cooling tower

Cooling tower — 2217 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 58.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2J18 cooling tower

Cooling tower — 1849 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 48.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2J21 cooling tower

Cooling tower — 2046 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 54.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2J24 cooling tower

Cooling tower — 2221 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 58.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2J28 cooling tower

Cooling tower — 2467 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 66.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2K24 cooling tower

Cooling tower — 2449 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 64.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2K28 cooling tower

Cooling tower — 2725 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 72.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-2L28 cooling tower

Cooling tower — 2971 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 77.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3G18 cooling tower

Cooling tower — 1367 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3G21 cooling tower

Cooling tower — 1520 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3H18 cooling tower

Cooling tower — 1612 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 38.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3H21 cooling tower

Cooling tower — 1796 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 42.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3H24 cooling tower

Cooling tower — 1980 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 46.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3H28 cooling tower

Cooling tower — 2199 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 52.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3I18 cooling tower

Cooling tower — 1770 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 41.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3I21 cooling tower

Cooling tower — 1963 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 46.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3I24 cooling tower

Cooling tower — 2217 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 50.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3I28 cooling tower

Cooling tower — 2467 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 57.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3J18 cooling tower

Cooling tower — 2064 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 47.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3J21 cooling tower

Cooling tower — 2270 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 53.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3J24 cooling tower

Cooling tower — 2502 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 57.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3J28 cooling tower

Cooling tower — 2773 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 65.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 29-3K21 cooling tower

Cooling tower — 2532 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 58.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
‹ Previous1…2930313233…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.