Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 697–720 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Copeland 3DEHR10ME-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 35.9 kW cooling, 10.95 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Chicago Blower Design 51 airfoil plenum fan, size 730 (804 rpm; 200 HP motor assumed) CatalogFansChicago BlowerFan rated 37.28 m³/s at 122.44 kW.NAOpen in the builder
Grundfos TP 150-220/4 in-line pump, 4-pole CatalogPumpsGrundfosPump rated 50.74 kg/s at 15.50 kW.EUOpen in the builder
King KFUH4830-1-2S1-ECM electric unit heater (30 kW, 480 V 1-phase) CatalogHeatersKing ElectricAir heater, 30.0 kW at 0.98 m³/s.NAOpen in the builder
Danfoss LLZ013T2 (R404A scroll, 50 Hz, LT) CatalogCompressorsDanfossR404A compressor — 3.2 kW cooling, 2.09 kW input, COP 1.52 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Greenheck GB-240HP belt-drive high-pressure centrifugal roof downblast exhaust fan (1240 rpm, 3 HP) CatalogFansGreenheckFan rated 2.25 m³/s at 2.53 kW.NAOpen in the builder
Grundfos TP 150-240/4 in-line pump, 4-pole CatalogPumpsGrundfosPump rated 54.27 kg/s at 15.18 kW.EUOpen in the builder
King KFUH4830-3-2S3-ECM electric unit heater (30 kW, 480 V 3-phase) CatalogHeatersKing ElectricAir heater, 30.0 kW at 0.98 m³/s.NAOpen in the builder
Embraco EMH60HER (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.14 kW cooling, 0.10 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Soler & Palau STXB size 18 high-pressure belt-drive upblast roof exhauster (1550 rpm, 2 HP) CatalogFansSoler & PalauFan rated 1.32 m³/s at 1.72 kW.NAOpen in the builder
Grundfos TP 150-250/4 in-line pump, 4-pole CatalogPumpsGrundfosPump rated 56.24 kg/s at 18.06 kW.EUOpen in the builder
King KFUH4835-1-2S1-ECM electric unit heater (34.5 kW, 480 V 1-phase) CatalogHeatersKing ElectricAir heater, 34.5 kW at 0.98 m³/s.NAOpen in the builder
Invotech YM102A5G-100 (R22 medium-temperature refrigeration scroll, 60 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 19.6 kW cooling, 6.55 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Ziehl-Abegg FPowlet FP050-ZIL.0F.V3P1 art. 198430 (axial on mounting plate Ø500, EC 1~ 230 V, round full bell mouth) CatalogFansZiehl-AbeggFan rated 0.97 m³/s at 0.16 kW.EUOpen in the builder
Grundfos TP 150-260/4 in-line pump, 4-pole CatalogPumpsGrundfosPump rated 44.98 kg/s at 14.94 kW.EUOpen in the builder
King KFUH4835-3-2S3-ECM electric unit heater (34.5 kW, 480 V 3-phase) CatalogHeatersKing ElectricAir heater, 34.5 kW at 0.98 m³/s.NAOpen in the builder
Tecumseh CAJ4492Y (R134a recip, EN 12900) CatalogCompressorsTecumsehR134a compressor — 2.1 kW cooling, 1.01 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
CaptiveAire SIF11DD-HE direct-drive inline exhaust fan (Catalog #110C, November 2024; 3066 rpm) CatalogFansCaptiveAireFan rated 0.61 m³/s at 1.19 kW.NAOpen in the builder
Grundfos TP 150-270/4 in-line pump, 4-pole CatalogPumpsGrundfosPump rated 54.17 kg/s at 16.87 kW.EUOpen in the builder
King KFUH4840-3-2S3-ECM electric unit heater (40 kW, 480 V 3-phase) CatalogHeatersKing ElectricAir heater, 40.0 kW at 1.38 m³/s.NAOpen in the builder
BITZER GSD80295VL (R32 scroll, EN 12900) CatalogCompressorsBitzerR32 compressor — 71.2 kW cooling, 24.33 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Chicago Blower Design 51 airfoil plenum fan, size 807 (674 rpm; 200 HP motor assumed) CatalogFansChicago BlowerFan rated 43.89 m³/s at 125.94 kW.NAOpen in the builder
Grundfos TP 150-280/4 in-line pump, 4-pole CatalogPumpsGrundfosPump rated 48.26 kg/s at 17.62 kW.EUOpen in the builder
King KFUH4850-3-2S3-ECM electric unit heater (50 kW, 480 V 3-phase) CatalogHeatersKing ElectricAir heater, 50.0 kW at 1.60 m³/s.NAOpen in the builder
‹ Previous1…2829303132…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one