Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 15,385–15,408 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Copeland ZB95K5E-TFD (R513A scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R513A compressor — 23.3 kW cooling, 8.24 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB95K5E-TFD (R513A scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R513A compressor — 28.0 kW cooling, 9.89 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZB95K5E-TFE (R404A scroll, 60 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 27.7 kW cooling, 9.12 kW input, COP 3.04 at -15/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Copeland ZB95KC-TED (R22 scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R22 compressor — 34.6 kW cooling, 11.34 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB95KC-TED (R22 scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R22 compressor — 42.3 kW cooling, 14.15 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZB95KCE-TED (R134A scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 27.6 kW cooling, 9.73 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZB95KCE-TED (R22 scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R22 compressor — 34.6 kW cooling, 11.34 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB95KCE-TED (R22 scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R22 compressor — 42.3 kW cooling, 14.15 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Copeland ZB95KCE-TED (R404A scroll, 60 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 20.8 kW cooling, 10.30 kW input, COP 2.02 at -20/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Copeland ZB95KCE-TFD (R134A scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 23.2 kW cooling, 7.98 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Copeland ZB95KCE-TFD (R404A scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 17.3 kW cooling, 8.24 kW input, COP 2.10 at -20/35 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Copeland ZB95KCE-TFD (R507 scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R507 compressor — 18.1 kW cooling, 8.48 kW input, COP 2.13 at -20/35 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Copeland ZB95KQ-TFD (R22 scroll, 50 Hz, HD) Catalog | Compressors | Copeland | R22 compressor — 34.6 kW cooling, 11.34 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB95KQ-TFD (R22 scroll, 60 Hz, HD) Catalog | Compressors | Copeland | R22 compressor — 42.3 kW cooling, 14.15 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB95KQE-TF7 (R407C scroll, 60 Hz, HD) Catalog | Compressors | Copeland | R407C compressor — 40.2 kW cooling, 13.86 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB95KQE-TFD (R134A scroll, 50 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 23.0 kW cooling, 7.86 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB95KQE-TFD (R134A scroll, 60 Hz, HT) Catalog | Compressors | Copeland | R134a compressor — 27.6 kW cooling, 9.73 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB95KQE-TFD (R404A scroll, 50 Hz, MD) Catalog | Compressors | Copeland | R404A compressor — 32.7 kW cooling, 13.21 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB95KQE-TFD (R404A scroll, 60 Hz, MD) Catalog | Compressors | Copeland | R404A compressor — 39.7 kW cooling, 16.22 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point. | APAC | Open in the builder |
| Copeland ZB97K5U-TFM (R290 scroll, 50 Hz, MT) Catalog | Compressors | Copeland | R290 compressor — 35.3 kW cooling, 11.50 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Example R410A scroll, 12 kW class Example | Compressors | HVAC Builder | R410A compressor — 11.9 kW cooling, 3.86 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point. | EU, NA | Open in the builder |
| Example DX coil, 3-row 600 × 600 Example | Coils | HVAC Builder | Fin-and-tube coil, 600 × 600 mm face, 3 rows at 12.0 fpi, 0.90 m³/s design air flow. | EU | Open in the builder |
| Example plug fan, 4.0 m³/s Fictional | Fans | Aeronim Systems (fictional) | Fan rated 4.00 m³/s at 3.00 kW. | EU | Open in the builder |
| Example inline circulator, 4.0 kg/s Fictional | Pumps | Aeronim Systems (fictional) | Pump rated 4.00 kg/s at 0.55 kW. | EU | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one