Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 3073–3096 of 3346
Baltimore Aircoil's VRC-0445B-1212N-MA — a Vertex VRC evaporative condenser rejecting 2697 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 40.2 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0469B-1212N-NA — a Vertex VRC evaporative condenser rejecting 2848 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 43.3 m³/s of the maker's own printed air, with a 37.3 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0467B-1218N-HB — a Vertex VRC evaporative condenser rejecting 2829 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 56.6 m³/s of the maker's own printed air, with a 25.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0516B-1218N-JB — a Vertex VRC evaporative condenser rejecting 3126 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 65.7 m³/s of the maker's own printed air, with a 40.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0510B-1218N-HB — a Vertex VRC evaporative condenser rejecting 3093 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 54.3 m³/s of the maker's own printed air, with a 25.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0564B-1218N-JB — a Vertex VRC evaporative condenser rejecting 3419 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 63.0 m³/s of the maker's own printed air, with a 40.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0555B-1218N-HB — a Vertex VRC evaporative condenser rejecting 3369 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 51.3 m³/s of the maker's own printed air, with a 25.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0614B-1218N-JB — a Vertex VRC evaporative condenser rejecting 3723 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 59.6 m³/s of the maker's own printed air, with a 40.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0599B-1218N-HB — a Vertex VRC evaporative condenser rejecting 3633 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 47.1 m³/s of the maker's own printed air, with a 25.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0662B-1218N-JB — a Vertex VRC evaporative condenser rejecting 4015 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 54.6 m³/s of the maker's own printed air, with a 40.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0374B-1218N-HA — a Vertex VRC evaporative condenser rejecting 2266 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 42.3 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0413B-1218N-JA — a Vertex VRC evaporative condenser rejecting 2503 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 48.5 m³/s of the maker's own printed air, with a 16.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0442B-1218N-KA — a Vertex VRC evaporative condenser rejecting 2684 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 53.3 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0414B-1218N-HA — a Vertex VRC evaporative condenser rejecting 2507 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 41.1 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0456B-1218N-JA — a Vertex VRC evaporative condenser rejecting 2766 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 47.0 m³/s of the maker's own printed air, with a 16.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0489B-1218N-KA — a Vertex VRC evaporative condenser rejecting 2964 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 51.8 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0533B-1218N-KA — a Vertex VRC evaporative condenser rejecting 3231 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 50.4 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0587B-1218N-LA — a Vertex VRC evaporative condenser rejecting 3563 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 57.7 m³/s of the maker's own printed air, with a 33.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0630B-1218N-MA — a Vertex VRC evaporative condenser rejecting 3821 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 63.5 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0636B-1218N-LA — a Vertex VRC evaporative condenser rejecting 3856 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 54.3 m³/s of the maker's own printed air, with a 33.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0680B-1218N-MA — a Vertex VRC evaporative condenser rejecting 4123 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 59.5 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0717B-1218N-NA — a Vertex VRC evaporative condenser rejecting 4351 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 64.1 m³/s of the maker's own printed air, with a 55.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0538B-1024N-HB — a Vertex VRC evaporative condenser rejecting 3264 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 78.7 m³/s of the maker's own printed air, with a 38.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
Baltimore Aircoil's VRC-0595B-1024N-JB — a Vertex VRC evaporative condenser rejecting 3608 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 91.3 m³/s of the maker's own printed air, with a 60.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.