Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 361–384 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 112-2M18 cooling tower (552 tons, 2.4 MW) — modelled Example modelled from published data EVAPCO's 112-2M18 — an AT cooling tower, 552 nominal tons (2427 kW): rated to cool 1662 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 64.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1820–3034 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-0709A-3L cooling tower (209 tons, 920 kW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-0709A-3L — a PT2 cooling tower, 209 nominal tons (920 kW): rated to cool 630 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 690–1150 kW | EU | Open in the builder |
| EVAPCO ATWB 12-3M40 closed-circuit cooler (816 tons, 3.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 12-3M40 — an ATWB closed-circuit cooler, 816 nominal tons (3586 kW): rated to cool 2046 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 125.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2690–4483 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-09JN cooling tower (327 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-09JN — a Series 1500 cooling tower, 327 nominal tons (1437 kW): rated to cool 984 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 35.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1078–1796 kW | EU | Open in the builder |
| EVAPCO AT 112-2M20 cooling tower (542 tons, 2.4 MW) — modelled Example modelled from published data EVAPCO's 112-2M20 — an AT cooling tower, 542 nominal tons (2383 kW): rated to cool 1632 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 66.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1788–2979 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1020-07M cooling tower (424 tons, 1.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1020-07M — a Series 3000 cooling tower, 424 nominal tons (1862 kW): rated to cool 1275 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 49.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1397–2328 kW | EU | Open in the builder |
| EVAPCO ATWB 12-3N14 closed-circuit cooler (328 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 12-3N14 — an ATWB closed-circuit cooler, 328 nominal tons (1441 kW): rated to cool 822 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 51.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1081–1802 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT0-155-N cooling tower (154 tons, 679 kW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓ BAC's VT0-155-N — a Series V cooling tower, 154 nominal tons (679 kW): rated to cool 465 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 509–849 kW | EU | Open in the builder |
| EVAPCO AT 112-2N18 cooling tower (608 tons, 2.7 MW) — modelled Example modelled from published data EVAPCO's 112-2N18 — an AT cooling tower, 608 nominal tons (2673 kW): rated to cool 1830 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 71.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2004–3341 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-009-42G closed-circuit cooler (9 tons, 39 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-009-42G — a Series V closed circuit closed-circuit cooler, 9 nominal tons (39 kW): rated to cool 27 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 2.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 30–49 kW | EU | Open in the builder |
| EVAPCO ATWB 12-3N20 closed-circuit cooler (452 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 12-3N20 — an ATWB closed-circuit cooler, 452 nominal tons (1986 kW): rated to cool 1133 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 68.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1490–2483 kW | EU | Open in the builder |
| Baltimore Aircoil VCL-048 evaporative condenser (207 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCL-048 — a Series V EC evaporative condenser rejecting 207 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 6.7 m³/s of the maker's own printed air, with a 2.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 155–259 kW | EU | Open in the builder |
| EVAPCO AT 112-2N20 cooling tower (623 tons, 2.7 MW) — modelled Example modelled from published data EVAPCO's 112-2N20 — an AT cooling tower, 623 nominal tons (2738 kW): rated to cool 1875 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 72.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2054–3423 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-1075A evaporative condenser (4.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-1075A — a VCA evaporative condenser rejecting 4631 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 63.5 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 3474–5789 kW | EU | Open in the builder |
| EVAPCO ATWB 12-3N28 closed-circuit cooler (656 tons, 2.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 12-3N28 — an ATWB closed-circuit cooler, 656 nominal tons (2883 kW): rated to cool 1645 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 102.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2162–3603 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0268B-1212N-JA evaporative condenser (1.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0268B-1212N-JA — a Vertex VRC evaporative condenser rejecting 1624 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 32.3 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1218–2030 kW | EU | Open in the builder |
| EVAPCO AT 112-2O20 cooling tower (677 tons, 3.0 MW) — modelled Example modelled from published data EVAPCO's 112-2O20 — an AT cooling tower, 677 nominal tons (2975 kW): rated to cool 2037 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 78.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2231–3719 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-113-0809-3 evaporative condenser (685 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-113-0809-3 — a CXVB evaporative condenser rejecting 685 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 14.7 m³/s of the maker's own printed air, with a 2.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 513–856 kW | EU | Open in the builder |
| EVAPCO ATWB 12-3N36 closed-circuit cooler (823 tons, 3.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 12-3N36 — an ATWB closed-circuit cooler, 823 nominal tons (3620 kW): rated to cool 2066 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 126.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2715–4525 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-1462-2424-100 evaporative condenser (8.9 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-1462-2424-100 — a CXVT evaporative condenser rejecting 8881 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 185.3 m³/s of the maker's own printed air, with a 74.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 6660–11101 kW | EU | Open in the builder |
| EVAPCO AT 112-3I12 cooling tower (315 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 112-3I12 — an AT cooling tower, 315 nominal tons (1385 kW): rated to cool 948 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 33.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1038–1731 kW | EU | Open in the builder |
| Baltimore Aircoil FXT-0706B-J cooling tower (95 tons, 416 kW) — modelled Example modelled from published data BAC's FXT-0706B-J — an FXT cooling tower, 95 nominal tons (416 kW): rated to cool 285 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 13.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 312–520 kW | EU | Open in the builder |
| EVAPCO ATWB 12-3N40 closed-circuit cooler (897 tons, 3.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 12-3N40 — an ATWB closed-circuit cooler, 897 nominal tons (3944 kW): rated to cool 2251 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 136.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2958–4930 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0806B-24D-L closed-circuit cooler (78 tons, 342 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0806B-24D-L — an FXV closed-circuit cooler, 78 nominal tons (342 kW): rated to cool 234 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 19.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 256–427 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers