Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 385–408 of 3,474

NameCompanyCategoryCapacityMarketsOpen in the builder
EVAPCO AT 112-3I14 cooling tower (343 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 112-3I14 — an AT cooling tower, 343 nominal tons (1507 kW): rated to cool 1032 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 36.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1130–1884 kWEUOpen in the builder
Baltimore Aircoil Nexus NXF-0603N-CS2TT-J2 closed-circuit cooler (60 tons, 263 kW) — modelled Example modelled from published data
BAC's NXF-0603N-CS2TT-J2 — a Nexus closed-circuit cooler, 60 nominal tons (263 kW): rated to cool 180 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 12.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection197–329 kWEUOpen in the builder
EVAPCO ATWB 12-3O20 closed-circuit cooler (486 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 12-3O20 — an ATWB closed-circuit cooler, 486 nominal tons (2137 kW): rated to cool 1219 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 72.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1603–2671 kWEUOpen in the builder
Baltimore Aircoil PCC-0117-0709N7.5 evaporative condenser (711 kW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0117-0709N7.5 — a PCC evaporative condenser rejecting 711 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 16.9 m³/s of the maker's own printed air, with a 5.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection533–888 kWEUOpen in the builder
EVAPCO AT 112-3J12 cooling tower (369 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 112-3J12 — an AT cooling tower, 369 nominal tons (1621 kW): rated to cool 1110 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 37.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1216–2026 kWEUOpen in the builder
Baltimore Aircoil PFI-0406N-6D2DZ-H1 closed-circuit cooler (32 tons, 140 kW) — modelled Example modelled from published data
BAC's PFI-0406N-6D2DZ-H1 — a PFi closed-circuit cooler, 32 nominal tons (140 kW): rated to cool 96 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 6.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection105–175 kWEUOpen in the builder
EVAPCO ATWB 12-3O40 closed-circuit cooler (965 tons, 4.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 12-3O40 — an ATWB closed-circuit cooler, 965 nominal tons (4243 kW): rated to cool 2421 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 145.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection3182–5304 kWEUOpen in the builder
Baltimore Aircoil PT2-0709A-4L cooling tower (213 tons, 938 kW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓
BAC's PT2-0709A-4L — a PT2 cooling tower, 213 nominal tons (938 kW): rated to cool 642 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection703–1172 kWEUOpen in the builder
EVAPCO AT 112-3J14 cooling tower (404 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 112-3J14 — an AT cooling tower, 404 nominal tons (1774 kW): rated to cool 1215 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 41.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1331–2218 kWEUOpen in the builder
Baltimore Aircoil Series 1500 S15E-1212-09JN-2 cooling tower (654 tons, 2.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S15E-1212-09JN-2 — a Series 1500 cooling tower, 654 nominal tons (2874 kW): rated to cool 1968 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 70.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2156–3593 kWEUOpen in the builder
EVAPCO ATWB 12-4K14 closed-circuit cooler (278 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 12-4K14 — an ATWB closed-circuit cooler, 278 nominal tons (1224 kW): rated to cool 699 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 40.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection918–1530 kWEUOpen in the builder
Baltimore Aircoil Series 3000 S3E-1020-07M-2 cooling tower (848 tons, 3.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S3E-1020-07M-2 — a Series 3000 cooling tower, 848 nominal tons (3729 kW): rated to cool 2553 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 99.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2796–4661 kWEUOpen in the builder
EVAPCO AT 112-3J18 cooling tower (486 tons, 2.1 MW) — modelled Example modelled from published data
EVAPCO's 112-3J18 — an AT cooling tower, 486 nominal tons (2138 kW): rated to cool 1464 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 51.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1604–2673 kWEUOpen in the builder
Baltimore Aircoil Series V VT0-166-N cooling tower (165 tons, 727 kW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓
BAC's VT0-166-N — a Series V cooling tower, 165 nominal tons (727 kW): rated to cool 498 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection545–909 kWEUOpen in the builder
EVAPCO ATWB 12-4K28 closed-circuit cooler (557 tons, 2.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 12-4K28 — an ATWB closed-circuit cooler, 557 nominal tons (2448 kW): rated to cool 1397 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 81.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1836–3061 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-018-12F closed-circuit cooler (9 tons, 39 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓
BAC's VF1-018-12F — a Series V closed circuit closed-circuit cooler, 9 nominal tons (39 kW): rated to cool 27 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 3.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection30–49 kWEUOpen in the builder
EVAPCO AT 112-3K12 cooling tower (403 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 112-3K12 — an AT cooling tower, 403 nominal tons (1770 kW): rated to cool 1212 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 41.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1328–2213 kWEUOpen in the builder
Baltimore Aircoil VCL-054 evaporative condenser (233 kW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCL-054 — a Series V EC evaporative condenser rejecting 233 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 7.6 m³/s of the maker's own printed air, with a 3.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection175–291 kWEUOpen in the builder
EVAPCO ATWB 12-4K36 closed-circuit cooler (691 tons, 3.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 12-4K36 — an ATWB closed-circuit cooler, 691 nominal tons (3039 kW): rated to cool 1734 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 99.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2279–3799 kWEUOpen in the builder
Baltimore Aircoil VCA-1082A evaporative condenser (4.7 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-1082A — a VCA evaporative condenser rejecting 4661 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 76.9 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection3496–5827 kWEUOpen in the builder
EVAPCO AT 112-3K14 cooling tower (438 tons, 1.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 112-3K14 — an AT cooling tower, 438 nominal tons (1923 kW): rated to cool 1317 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 45.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1443–2404 kWEUOpen in the builder
Baltimore Aircoil VRC-0269B-1012N-HB evaporative condenser (1.6 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0269B-1012N-HB — a Vertex VRC evaporative condenser rejecting 1632 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 39.4 m³/s of the maker's own printed air, with a 19.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1224–2040 kWEUOpen in the builder
EVAPCO ATWB 12-4L14 closed-circuit cooler (300 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 12-4L14 — an ATWB closed-circuit cooler, 300 nominal tons (1321 kW): rated to cool 754 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 43.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection991–1651 kWEUOpen in the builder
Baltimore Aircoil CXVB-1134-1236-75 evaporative condenser (6.9 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVB-1134-1236-75 — a CXVB evaporative condenser rejecting 6870 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 133.4 m³/s of the maker's own printed air, with a 59.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection5153–8588 kWEUOpen in the builder
‹ Previous1…1516171819…145Next ›