Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 961–984 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 19-2F6 cooling tower (89 tons, 390 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2F6 — an AT cooling tower, 89 nominal tons (390 kW): rated to cool 267 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 10.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 292–487 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-3D4ES-J1 closed-circuit cooler (61 tons, 267 kW) — modelled Example modelled from published data BAC's PFI-0709N-3D4ES-J1 — a PFi closed-circuit cooler, 61 nominal tons (267 kW): rated to cool 183 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 15.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 200–334 kW | EU | Open in the builder |
| EVAPCO ATWB 20-6K18 closed-circuit cooler (710 tons, 3.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-6K18 — an ATWB closed-circuit cooler, 710 nominal tons (3121 kW): rated to cool 1781 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 79.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2341–3901 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-1009A-5N cooling tower (318 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-1009A-5N — a PT2 cooling tower, 318 nominal tons (1398 kW): rated to cool 957 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 29.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1048–1747 kW | EU | Open in the builder |
| EVAPCO AT 19-2F8 cooling tower (109 tons, 478 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2F8 — an AT cooling tower, 109 nominal tons (478 kW): rated to cool 327 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 12.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 358–597 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-11MN cooling tower (476 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-11MN — a Series 1500 cooling tower, 476 nominal tons (2094 kW): rated to cool 1434 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 50.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1571–2618 kW | EU | Open in the builder |
| EVAPCO ATWB 20-6K36 closed-circuit cooler (1356 tons, 6.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-6K36 — an ATWB closed-circuit cooler, 1356 nominal tons (5960 kW): rated to cool 3401 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 158.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4470–7450 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-07R cooling tower (688 tons, 3.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-07R — a Series 3000 cooling tower, 688 nominal tons (3023 kW): rated to cool 2070 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 79.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2267–3779 kW | EU | Open in the builder |
| EVAPCO AT 19-2G11 cooling tower (155 tons, 683 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2G11 — an AT cooling tower, 155 nominal tons (683 kW): rated to cool 468 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 19.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 513–854 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-375-P cooling tower (374 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓ BAC's VT1-375-P — a Series V cooling tower, 374 nominal tons (1643 kW): rated to cool 1125 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 37.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1232–2054 kW | EU | Open in the builder |
| EVAPCO ATWB 20-6L18 closed-circuit cooler (762 tons, 3.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-6L18 — an ATWB closed-circuit cooler, 762 nominal tons (3352 kW): rated to cool 1912 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 85.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2514–4189 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-036-22K closed-circuit cooler (39 tons, 171 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-036-22K — a Series V closed circuit closed-circuit cooler, 39 nominal tons (171 kW): rated to cool 117 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 10.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 128–214 kW | EU | Open in the builder |
| EVAPCO AT 19-2G6 cooling tower (112 tons, 491 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2G6 — an AT cooling tower, 112 nominal tons (491 kW): rated to cool 336 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 12.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 368–613 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-1422A evaporative condenser (6.1 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-1422A — a VCA evaporative condenser rejecting 6126 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 101.1 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 4595–7658 kW | EU | Open in the builder |
| EVAPCO ATWB 20-6L36 closed-circuit cooler (1456 tons, 6.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-6L36 — an ATWB closed-circuit cooler, 1456 nominal tons (6403 kW): rated to cool 3653 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 171.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4802–8003 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0348B-1212N-JB evaporative condenser (2.1 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0348B-1212N-JB — a Vertex VRC evaporative condenser rejecting 2105 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 46.7 m³/s of the maker's own printed air, with a 30.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1579–2632 kW | EU | Open in the builder |
| EVAPCO AT 19-2G8 cooling tower (137 tons, 600 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2G8 — an AT cooling tower, 137 nominal tons (600 kW): rated to cool 411 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 14.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 450–750 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-207-0809-20 evaporative condenser (1.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-207-0809-20 — a CXVB evaporative condenser rejecting 1254 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 26.4 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 941–1568 kW | EU | Open in the builder |
| EVAPCO ATWB 20-6M18 closed-circuit cooler (808 tons, 3.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-6M18 — an ATWB closed-circuit cooler, 808 nominal tons (3551 kW): rated to cool 2026 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 90.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2664–4439 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-754-1224-60 evaporative condenser (4.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-754-1224-60 — a CXVT evaporative condenser rejecting 4579 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 98.4 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 3434–5724 kW | EU | Open in the builder |
| EVAPCO AT 19-2G9 cooling tower (135 tons, 591 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2G9 — an AT cooling tower, 135 nominal tons (591 kW): rated to cool 405 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 444–739 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0812A-23T-M closed-circuit cooler (132 tons, 578 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0812A-23T-M — an FXV closed-circuit cooler, 132 nominal tons (578 kW): rated to cool 396 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 30.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 434–723 kW | EU | Open in the builder |
| EVAPCO ATWB 20-6M36 closed-circuit cooler (1544 tons, 6.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-6M36 — an ATWB closed-circuit cooler, 1544 nominal tons (6786 kW): rated to cool 3872 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 180.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5090–8483 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0269-1012N030 evaporative condenser (1.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0269-1012N030 — a PCC evaporative condenser rejecting 1634 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 40.0 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1225–2042 kW | EU | Open in the builder |