Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 26Systems 3346Components 10248
All categoriesCooling tower / heat rejection 3307VRF / multi-split 8Air handler 7Plant / central 5Fan coil / terminal 4Condensing unit 3Rooftop / packaged 3Split system 3Chiller 2Heat recovery / DOAS 2Evaporative air cooler 1Unit cooler / refrigeration 1
All manufacturersBaltimore Aircoil 1900EVAPCO 1408Midea 2Gree 1Hitachi 1Samsung 1
All seriesAT 992ATWB 416PFi 359PCC 214Series 3000 189Series 1500 173Series V closed circuit 173Vertex VRC 157VCA 151Series V 122CXVB 118FXV 100PT2 46CXVT 40Series V EC 26FXT 20Nexus 12DVM S 1GMV5 1Set Free FSXN 1V4+ 1V6 1
Any capacity500 kW and up 3088100–500 kW 39125–100 kW 76up to 25 kW 25
Any certificationCTI STD-201 (validation C13A-99R28) 822CTI STD-201 (validation C13F-09R12) 416CTI STD-201 (validation C11F-92R20) 362CTI STD-201 (validation C11K-00R03) 153CTI STD-201 (validation C11J-98R12) 100CTI STD-201 (validation C11B-92R07) 90CTI STD-201 (validation C11L-07R05) 46CTI STD-201 (validation C11Q-18R02) 2
All marketsEU 3346
All tagsexample 3346
All suppliersHVAC Builder 3345Aeronim Systems (fictional) 1
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 961–984 of 3346

Baltimore Aircoil PFI-2412N-3D2DS-O2 closed-circuit cooler (306 tons, 1.3 MW) — modelled

BAC's PFI-2412N-3D2DS-O2 — a PFi closed-circuit cooler, 306 nominal tons (1345 kW): rated to cool 921 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 92.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1009–1681 kW · EU

Baltimore Aircoil PFI-2418N-4D2ES-R2 closed-circuit cooler (641 tons, 2.8 MW) — modelled

BAC's PFI-2418N-4D2ES-R2 — a PFi closed-circuit cooler, 641 nominal tons (2817 kW): rated to cool 1929 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 140.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 2113–3522 kW · EU

Baltimore Aircoil PFI-1012N-2D2ES-L1 closed-circuit cooler (90 tons, 394 kW) — modelled

BAC's PFI-1012N-2D2ES-L1 — a PFi closed-circuit cooler, 90 nominal tons (394 kW): rated to cool 270 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 32.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 296–493 kW · EU

Baltimore Aircoil PFI-1024N-3D4DS-M2 closed-circuit cooler (251 tons, 1.1 MW) — modelled

BAC's PFI-1024N-3D4DS-M2 — a PFi closed-circuit cooler, 251 nominal tons (1104 kW): rated to cool 756 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 65.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 828–1380 kW · EU

Baltimore Aircoil PFI-2412N-5D1DS-O2 closed-circuit cooler (375 tons, 1.6 MW) — modelled

BAC's PFI-2412N-5D1DS-O2 — a PFi closed-circuit cooler, 375 nominal tons (1647 kW): rated to cool 1128 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 87.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1236–2059 kW · EU

Baltimore Aircoil PFI-2418N-4D4ES-R2 closed-circuit cooler (666 tons, 2.9 MW) — modelled

BAC's PFI-2418N-4D4ES-R2 — a PFi closed-circuit cooler, 666 nominal tons (2927 kW): rated to cool 2004 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 131.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 2195–3658 kW · EU

Baltimore Aircoil PFI-1012N-2D4ES-N1 closed-circuit cooler (106 tons, 464 kW) — modelled

BAC's PFI-1012N-2D4ES-N1 — a PFi closed-circuit cooler, 106 nominal tons (464 kW): rated to cool 318 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 36.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 348–581 kW · EU

Baltimore Aircoil PFI-1024N-3D3DS-N2 closed-circuit cooler (259 tons, 1.1 MW) — modelled

BAC's PFI-1024N-3D3DS-N2 — a PFi closed-circuit cooler, 259 nominal tons (1139 kW): rated to cool 780 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 73.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 854–1424 kW · EU

Baltimore Aircoil PFI-2412N-3D1DS-P2 closed-circuit cooler (313 tons, 1.4 MW) — modelled

BAC's PFI-2412N-3D1DS-P2 — a PFi closed-circuit cooler, 313 nominal tons (1376 kW): rated to cool 942 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 105.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1032–1720 kW · EU

Baltimore Aircoil PFI-2418N-6D3ES-R2 closed-circuit cooler (703 tons, 3.1 MW) — modelled

BAC's PFI-2418N-6D3ES-R2 — a PFi closed-circuit cooler, 703 nominal tons (3089 kW): rated to cool 2115 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 123.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 2317–3861 kW · EU

Baltimore Aircoil PFI-1012N-4D2ES-N1 closed-circuit cooler (155 tons, 683 kW) — modelled

BAC's PFI-1012N-4D2ES-N1 — a PFi closed-circuit cooler, 155 nominal tons (683 kW): rated to cool 468 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 34.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 513–854 kW · EU

Baltimore Aircoil PFI-1024N-2D2ES-L2 closed-circuit cooler (178 tons, 784 kW) — modelled

BAC's PFI-1024N-2D2ES-L2 — a PFi closed-circuit cooler, 178 nominal tons (784 kW): rated to cool 537 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 64.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 588–980 kW · EU

Baltimore Aircoil PFI-2412N-4D3DS-P2 closed-circuit cooler (388 tons, 1.7 MW) — modelled

BAC's PFI-2412N-4D3DS-P2 — a PFi closed-circuit cooler, 388 nominal tons (1704 kW): rated to cool 1167 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 91.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1278–2130 kW · EU

Baltimore Aircoil PFI-2418N-6D1ES-R2 closed-circuit cooler (719 tons, 3.2 MW) — modelled

BAC's PFI-2418N-6D1ES-R2 — a PFi closed-circuit cooler, 719 nominal tons (3159 kW): rated to cool 2163 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 135.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 2369–3949 kW · EU

Baltimore Aircoil PFI-1012N-3D2ES-O1 closed-circuit cooler (140 tons, 613 kW) — modelled

BAC's PFI-1012N-3D2ES-O1 — a PFi closed-circuit cooler, 140 nominal tons (613 kW): rated to cool 420 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 38.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 460–767 kW · EU

Baltimore Aircoil PFI-1024N-2D4ES-N2 closed-circuit cooler (210 tons, 924 kW) — modelled

BAC's PFI-1024N-2D4ES-N2 — a PFi closed-circuit cooler, 210 nominal tons (924 kW): rated to cool 633 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 73.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 693–1156 kW · EU

Baltimore Aircoil PFI-2412N-2D4ES-M2 closed-circuit cooler (238 tons, 1.0 MW) — modelled

BAC's PFI-2412N-2D4ES-M2 — a PFi closed-circuit cooler, 238 nominal tons (1047 kW): rated to cool 717 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 78.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 785–1309 kW · EU

Baltimore Aircoil PFI-1012N-3D4ES-O1 closed-circuit cooler (147 tons, 644 kW) — modelled

BAC's PFI-1012N-3D4ES-O1 — a PFi closed-circuit cooler, 147 nominal tons (644 kW): rated to cool 441 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 36.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 483–805 kW · EU

Baltimore Aircoil PFI-1024N-4D2ES-N2 closed-circuit cooler (310 tons, 1.4 MW) — modelled

BAC's PFI-1024N-4D2ES-N2 — a PFi closed-circuit cooler, 310 nominal tons (1363 kW): rated to cool 933 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 69.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1022–1703 kW · EU

Baltimore Aircoil PFI-2412N-2D4ES-N2 closed-circuit cooler (249 tons, 1.1 MW) — modelled

BAC's PFI-2412N-2D4ES-N2 — a PFi closed-circuit cooler, 249 nominal tons (1095 kW): rated to cool 750 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 84.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 822–1369 kW · EU

Baltimore Aircoil PFI-0406N-3D1EZ-G1 closed-circuit cooler (20 tons, 88 kW) — modelled

BAC's PFI-0406N-3D1EZ-G1 — a PFi closed-circuit cooler, 20 nominal tons (88 kW): rated to cool 60 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 6.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 66–110 kW · EU

Baltimore Aircoil PFI-1012N-2D2DS-J1 closed-circuit cooler (75 tons, 329 kW) — modelled

BAC's PFI-1012N-2D2DS-J1 — a PFi closed-circuit cooler, 75 nominal tons (329 kW): rated to cool 225 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 27.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 246–411 kW · EU

Baltimore Aircoil PFI-1212N-3D2ES-L1 closed-circuit cooler (144 tons, 631 kW) — modelled

BAC's PFI-1212N-3D2ES-L1 — a PFi closed-circuit cooler, 144 nominal tons (631 kW): rated to cool 432 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 35.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 473–789 kW · EU

Baltimore Aircoil PFI-1218N-4D4DS-O1 closed-circuit cooler (264 tons, 1.2 MW) — modelled

BAC's PFI-1218N-4D4DS-O1 — a PFi closed-circuit cooler, 264 nominal tons (1161 kW): rated to cool 795 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 54.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 871–1451 kW · EU
‹ Previous1…3940414243…140Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers