Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 1,009–1,032 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 19-2I11 cooling tower (201 tons, 885 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2I11 — an AT cooling tower, 201 nominal tons (885 kW): rated to cool 606 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 23.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 664–1106 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-4D2ES-K1 closed-circuit cooler (74 tons, 324 kW) — modelled Example modelled from published data BAC's PFI-0709N-4D2ES-K1 — a PFi closed-circuit cooler, 74 nominal tons (324 kW): rated to cool 222 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 16.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 243–405 kW | EU | Open in the builder |
| EVAPCO ATWB 20-7N18 closed-circuit cooler (959 tons, 4.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-7N18 — an ATWB closed-circuit cooler, 959 nominal tons (4214 kW): rated to cool 2405 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 94.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3161–5268 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-1012A-2O cooling tower (367 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-1012A-2O — a PT2 cooling tower, 367 nominal tons (1612 kW): rated to cool 1104 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1209–2015 kW | EU | Open in the builder |
| EVAPCO AT 19-2I12 cooling tower (229 tons, 1.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2I12 — an AT cooling tower, 229 nominal tons (1008 kW): rated to cool 690 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 26.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 756–1260 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-12KN cooling tower (400 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-12KN — a Series 1500 cooling tower, 400 nominal tons (1757 kW): rated to cool 1203 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 42.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1318–2196 kW | EU | Open in the builder |
| EVAPCO ATWB 24-3J12 closed-circuit cooler (402 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-3J12 — an ATWB closed-circuit cooler, 402 nominal tons (1768 kW): rated to cool 1009 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 68.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1326–2210 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-10P cooling tower (754 tons, 3.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-10P — a Series 3000 cooling tower, 754 nominal tons (3317 kW): rated to cool 2271 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 85.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2488–4146 kW | EU | Open in the builder |
| EVAPCO AT 19-2I14 cooling tower (250 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2I14 — an AT cooling tower, 250 nominal tons (1100 kW): rated to cool 753 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 825–1375 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-415-R cooling tower (414 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓ BAC's VT1-415-R — a Series V cooling tower, 414 nominal tons (1818 kW): rated to cool 1245 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 42.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1364–2273 kW | EU | Open in the builder |
| EVAPCO ATWB 24-3K12 closed-circuit cooler (446 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-3K12 — an ATWB closed-circuit cooler, 446 nominal tons (1961 kW): rated to cool 1119 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 75.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1471–2451 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-036-31L closed-circuit cooler (44 tons, 193 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-036-31L — a Series V closed circuit closed-circuit cooler, 44 nominal tons (193 kW): rated to cool 132 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 11.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 145–241 kW | EU | Open in the builder |
| EVAPCO AT 19-2I8 cooling tower (158 tons, 697 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2I8 — an AT cooling tower, 158 nominal tons (697 kW): rated to cool 477 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 18.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 522–871 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-150A evaporative condenser (646 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-150A — a VCA evaporative condenser rejecting 646 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 13.4 m³/s of the maker's own printed air, with a 5.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 485–808 kW | EU | Open in the builder |
| EVAPCO ATWB 24-3K14 closed-circuit cooler (517 tons, 2.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-3K14 — an ATWB closed-circuit cooler, 517 nominal tons (2273 kW): rated to cool 1297 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 83.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1705–2841 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0356B-1012N-JB evaporative condenser (2.2 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0356B-1012N-JB — a Vertex VRC evaporative condenser rejecting 2161 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 34.3 m³/s of the maker's own printed air, with a 30.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1621–2702 kW | EU | Open in the builder |
| EVAPCO AT 19-2I9 cooling tower (177 tons, 780 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2I9 — an AT cooling tower, 177 nominal tons (780 kW): rated to cool 534 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 585–975 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-216-0812-7.5 evaporative condenser (1.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-216-0812-7.5 — a CXVB evaporative condenser rejecting 1309 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 24.4 m³/s of the maker's own printed air, with a 5.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 981–1636 kW | EU | Open in the builder |
| EVAPCO ATWB 24-3K28 closed-circuit cooler (987 tons, 4.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-3K28 — an ATWB closed-circuit cooler, 987 nominal tons (4340 kW): rated to cool 2476 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 167.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3255–5425 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-778-1224-50 evaporative condenser (4.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-778-1224-50 — a CXVT evaporative condenser rejecting 4728 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 92.0 m³/s of the maker's own printed air, with a 37.3 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 3546–5909 kW | EU | Open in the builder |
| EVAPCO AT 19-2J11 cooling tower (230 tons, 1.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2J11 — an AT cooling tower, 230 nominal tons (1012 kW): rated to cool 693 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 26.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 759–1265 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0812B-16D-O closed-circuit cooler (149 tons, 653 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0812B-16D-O — an FXV closed-circuit cooler, 149 nominal tons (653 kW): rated to cool 447 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 39.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 490–816 kW | EU | Open in the builder |
| EVAPCO ATWB 24-3L12 closed-circuit cooler (483 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-3L12 — an ATWB closed-circuit cooler, 483 nominal tons (2121 kW): rated to cool 1211 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 80.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1591–2652 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0278-0718N030 evaporative condenser (1.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0278-0718N030 — a PCC evaporative condenser rejecting 1689 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 41.2 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1267–2111 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers