| EVAPCO AT 19-2H11 cooling tower (186 tons, 819 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2H11 — an AT cooling tower, 186 nominal tons (819 kW): rated to cool 561 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 614–1024 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-4D2DS-M1 closed-circuit cooler (81 tons, 355 kW) — modelled Example modelled from published data BAC's PFI-0709N-4D2DS-M1 — a PFi closed-circuit cooler, 81 nominal tons (355 kW): rated to cool 243 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 21.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 266–444 kW | EU | Open in the builder |
| EVAPCO ATWB 20-6N18 closed-circuit cooler (885 tons, 3.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-6N18 — an ATWB closed-circuit cooler, 885 nominal tons (3888 kW): rated to cool 2219 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 97.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2916–4860 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-1012A-1O cooling tower (332 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-1012A-1O — a PT2 cooling tower, 332 nominal tons (1459 kW): rated to cool 999 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 44.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1094–1824 kW | EU | Open in the builder |
| EVAPCO AT 19-2H12 cooling tower (202 tons, 889 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2H12 — an AT cooling tower, 202 nominal tons (889 kW): rated to cool 609 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 23.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 667–1112 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-11MN-2 cooling tower (953 tons, 4.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-11MN-2 — a Series 1500 cooling tower, 953 nominal tons (4189 kW): rated to cool 2868 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 101.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3141–5236 kW | EU | Open in the builder |
| EVAPCO ATWB 20-7I18 closed-circuit cooler (618 tons, 2.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-7I18 — an ATWB closed-circuit cooler, 618 nominal tons (2717 kW): rated to cool 1550 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 61.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2037–3396 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-07R-2 cooling tower (1375 tons, 6.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-07R-2 — a Series 3000 cooling tower, 1375 nominal tons (6046 kW): rated to cool 4140 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 159.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4535–7558 kW | EU | Open in the builder |
| EVAPCO AT 19-2H14 cooling tower (220 tons, 968 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2H14 — an AT cooling tower, 220 nominal tons (968 kW): rated to cool 663 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 26.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 726–1210 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-400-Q cooling tower (399 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓ BAC's VT1-400-Q — a Series V cooling tower, 399 nominal tons (1753 kW): rated to cool 1200 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1314–2191 kW | EU | Open in the builder |
| EVAPCO ATWB 20-7J18 closed-circuit cooler (704 tons, 3.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-7J18 — an ATWB closed-circuit cooler, 704 nominal tons (3095 kW): rated to cool 1766 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 69.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2321–3869 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-036-22L closed-circuit cooler (47 tons, 206 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-036-22L — a Series V closed circuit closed-circuit cooler, 47 nominal tons (206 kW): rated to cool 141 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 11.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 154–257 kW | EU | Open in the builder |
| EVAPCO AT 19-2H6 cooling tower (123 tons, 539 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2H6 — an AT cooling tower, 123 nominal tons (539 kW): rated to cool 369 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 14.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 404–674 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-1501A evaporative condenser (6.5 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-1501A — a VCA evaporative condenser rejecting 6467 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 100.8 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 4850–8083 kW | EU | Open in the builder |
| EVAPCO ATWB 20-7K18 closed-circuit cooler (772 tons, 3.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-7K18 — an ATWB closed-circuit cooler, 772 nominal tons (3392 kW): rated to cool 1935 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 76.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2544–4240 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0349B-1212N-KA evaporative condenser (2.1 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0349B-1212N-KA — a Vertex VRC evaporative condenser rejecting 2115 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 33.6 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1587–2644 kW | EU | Open in the builder |
| EVAPCO AT 19-2H8 cooling tower (148 tons, 648 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2H8 — an AT cooling tower, 148 nominal tons (648 kW): rated to cool 444 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 486–811 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-207-0812-15 evaporative condenser (1.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-207-0812-15 — a CXVB evaporative condenser rejecting 1254 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 31.3 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 941–1568 kW | EU | Open in the builder |
| EVAPCO ATWB 20-7L18 closed-circuit cooler (828 tons, 3.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-7L18 — an ATWB closed-circuit cooler, 828 nominal tons (3639 kW): rated to cool 2076 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 82.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2729–4549 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-766-1426-30 evaporative condenser (4.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-766-1426-30 — a CXVT evaporative condenser rejecting 4654 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 85.1 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 3490–5817 kW | EU | Open in the builder |
| EVAPCO AT 19-2H9 cooling tower (161 tons, 710 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-2H9 — an AT cooling tower, 161 nominal tons (710 kW): rated to cool 486 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 19.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 532–887 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0812B-12D-O closed-circuit cooler (132 tons, 578 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0812B-12D-O — an FXV closed-circuit cooler, 132 nominal tons (578 kW): rated to cool 396 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 40.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 434–723 kW | EU | Open in the builder |
| EVAPCO ATWB 20-7M18 closed-circuit cooler (876 tons, 3.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-7M18 — an ATWB closed-circuit cooler, 876 nominal tons (3853 kW): rated to cool 2199 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 87.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2890–4816 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0272-1012N020 evaporative condenser (1.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0272-1012N020 — a PCC evaporative condenser rejecting 1652 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 33.0 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1239–2065 kW | EU | Open in the builder |