Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 26Systems 3346Components 10248
All categoriesCooling tower / heat rejection 3307VRF / multi-split 8Air handler 7Plant / central 5Fan coil / terminal 4Condensing unit 3Rooftop / packaged 3Split system 3Chiller 2Heat recovery / DOAS 2Evaporative air cooler 1Unit cooler / refrigeration 1
All manufacturersBaltimore Aircoil 1900EVAPCO 1408Midea 2Gree 1Hitachi 1Samsung 1
All seriesAT 992ATWB 416PFi 359PCC 214Series 3000 189Series 1500 173Series V closed circuit 173Vertex VRC 157VCA 151Series V 122CXVB 118FXV 100PT2 46CXVT 40Series V EC 26FXT 20Nexus 12DVM S 1GMV5 1Set Free FSXN 1V4+ 1V6 1
Any capacity500 kW and up 3088100–500 kW 39125–100 kW 76up to 25 kW 25
Any certificationCTI STD-201 (validation C13A-99R28) 822CTI STD-201 (validation C13F-09R12) 416CTI STD-201 (validation C11F-92R20) 362CTI STD-201 (validation C11K-00R03) 153CTI STD-201 (validation C11J-98R12) 100CTI STD-201 (validation C11B-92R07) 90CTI STD-201 (validation C11L-07R05) 46CTI STD-201 (validation C11Q-18R02) 2
All marketsEU 3346
All tagsexample 3346
All suppliersHVAC Builder 3345Aeronim Systems (fictional) 1
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 985–1008 of 3346

Baltimore Aircoil PFI-0406N-4D2DZ-G1 closed-circuit cooler (23 tons, 101 kW) — modelled

BAC's PFI-0406N-4D2DZ-G1 — a PFi closed-circuit cooler, 23 nominal tons (101 kW): rated to cool 69 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 6.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 76–126 kW · EU

Baltimore Aircoil PFI-1012N-2D4ES-K1 closed-circuit cooler (88 tons, 386 kW) — modelled

BAC's PFI-1012N-2D4ES-K1 — a PFi closed-circuit cooler, 88 nominal tons (386 kW): rated to cool 264 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 27.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 289–482 kW · EU

Baltimore Aircoil PFI-1212N-3D2ES-M1 closed-circuit cooler (152 tons, 670 kW) — modelled

BAC's PFI-1212N-3D2ES-M1 — a PFi closed-circuit cooler, 152 nominal tons (670 kW): rated to cool 459 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 39.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 503–838 kW · EU

Baltimore Aircoil PFI-1218N-4D4DS-P1 closed-circuit cooler (285 tons, 1.3 MW) — modelled

BAC's PFI-1218N-4D4DS-P1 — a PFi closed-circuit cooler, 285 nominal tons (1253 kW): rated to cool 858 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 59.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 940–1566 kW · EU

Baltimore Aircoil PFI-0406N-5D1EZ-G1 closed-circuit cooler (27 tons, 118 kW) — modelled

BAC's PFI-0406N-5D1EZ-G1 — a PFi closed-circuit cooler, 27 nominal tons (118 kW): rated to cool 81 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 5.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 89–148 kW · EU

Baltimore Aircoil PFI-1012N-3D1DS-L1 closed-circuit cooler (109 tons, 478 kW) — modelled

BAC's PFI-1012N-3D1DS-L1 — a PFi closed-circuit cooler, 109 nominal tons (478 kW): rated to cool 327 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 33.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 358–597 kW · EU

Baltimore Aircoil PFI-1212N-3D4DS-L1 closed-circuit cooler (138 tons, 605 kW) — modelled

BAC's PFI-1212N-3D4DS-L1 — a PFi closed-circuit cooler, 138 nominal tons (605 kW): rated to cool 414 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 34.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 453–756 kW · EU

Baltimore Aircoil PFI-1218N-4D4ES-Q1 closed-circuit cooler (318 tons, 1.4 MW) — modelled

BAC's PFI-1218N-4D4ES-Q1 — a PFi closed-circuit cooler, 318 nominal tons (1398 kW): rated to cool 957 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 61.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1048–1747 kW · EU

Baltimore Aircoil PFI-0406N-6D2DZ-H1 closed-circuit cooler (32 tons, 140 kW) — modelled

BAC's PFI-0406N-6D2DZ-H1 — a PFi closed-circuit cooler, 32 nominal tons (140 kW): rated to cool 96 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 6.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 105–175 kW · EU

Baltimore Aircoil PFI-1012N-3D2DS-K1 closed-circuit cooler (103 tons, 451 kW) — modelled

BAC's PFI-1012N-3D2DS-K1 — a PFi closed-circuit cooler, 103 nominal tons (451 kW): rated to cool 309 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 28.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 338–564 kW · EU

Baltimore Aircoil PFI-1212N-3D4ES-M1 closed-circuit cooler (157 tons, 692 kW) — modelled

BAC's PFI-1212N-3D4ES-M1 — a PFi closed-circuit cooler, 157 nominal tons (692 kW): rated to cool 474 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 36.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 519–865 kW · EU

Baltimore Aircoil PFI-1218N-5D2ES-Q1 closed-circuit cooler (329 tons, 1.4 MW) — modelled

BAC's PFI-1218N-5D2ES-Q1 — a PFi closed-circuit cooler, 329 nominal tons (1446 kW): rated to cool 990 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 63.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1084–1807 kW · EU

Baltimore Aircoil PFI-0412N-3D1DZ-G2 closed-circuit cooler (43 tons, 188 kW) — modelled

BAC's PFI-0412N-3D1DZ-G2 — a PFi closed-circuit cooler, 43 nominal tons (188 kW): rated to cool 129 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 12.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 141–235 kW · EU

Baltimore Aircoil PFI-1012N-3D2ES-L1 closed-circuit cooler (121 tons, 530 kW) — modelled

BAC's PFI-1012N-3D2ES-L1 — a PFi closed-circuit cooler, 121 nominal tons (530 kW): rated to cool 363 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 30.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 398–663 kW · EU

Baltimore Aircoil PFI-1212N-4D2DS-M1 closed-circuit cooler (161 tons, 710 kW) — modelled

BAC's PFI-1212N-4D2DS-M1 — a PFi closed-circuit cooler, 161 nominal tons (710 kW): rated to cool 486 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 38.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 532–887 kW · EU

Baltimore Aircoil PFI-1224N-2D4DS-K2 closed-circuit cooler (198 tons, 872 kW) — modelled

BAC's PFI-1224N-2D4DS-K2 — a PFi closed-circuit cooler, 198 nominal tons (872 kW): rated to cool 597 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 65.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 654–1090 kW · EU

Baltimore Aircoil PFI-0412N-3D2EZ-G2 closed-circuit cooler (48 tons, 210 kW) — modelled

BAC's PFI-0412N-3D2EZ-G2 — a PFi closed-circuit cooler, 48 nominal tons (210 kW): rated to cool 144 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 11.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 158–263 kW · EU

Baltimore Aircoil PFI-1012N-3D2ES-M1 closed-circuit cooler (129 tons, 565 kW) — modelled

BAC's PFI-1012N-3D2ES-M1 — a PFi closed-circuit cooler, 129 nominal tons (565 kW): rated to cool 387 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 33.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 424–706 kW · EU

Baltimore Aircoil PFI-1212N-4D2DS-N1 closed-circuit cooler (170 tons, 749 kW) — modelled

BAC's PFI-1212N-4D2DS-N1 — a PFi closed-circuit cooler, 170 nominal tons (749 kW): rated to cool 513 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 41.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 562–937 kW · EU

Baltimore Aircoil PFI-1224N-3D2DS-K2 closed-circuit cooler (245 tons, 1.1 MW) — modelled

BAC's PFI-1224N-3D2DS-K2 — a PFi closed-circuit cooler, 245 nominal tons (1078 kW): rated to cool 738 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 65.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 808–1347 kW · EU

Baltimore Aircoil PFI-0412N-4D1EZ-G2 closed-circuit cooler (54 tons, 237 kW) — modelled

BAC's PFI-0412N-4D1EZ-G2 — a PFi closed-circuit cooler, 54 nominal tons (237 kW): rated to cool 162 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 11.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 177–296 kW · EU

Baltimore Aircoil PFI-1012N-3D4DS-L1 closed-circuit cooler (118 tons, 517 kW) — modelled

BAC's PFI-1012N-3D4DS-L1 — a PFi closed-circuit cooler, 118 nominal tons (517 kW): rated to cool 354 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 30.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 388–646 kW · EU

Baltimore Aircoil PFI-1212N-4D3ES-M1 closed-circuit cooler (175 tons, 771 kW) — modelled

BAC's PFI-1212N-4D3ES-M1 — a PFi closed-circuit cooler, 175 nominal tons (771 kW): rated to cool 528 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 36.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 578–964 kW · EU

Baltimore Aircoil PFI-1224N-3D2DS-L2 closed-circuit cooler (265 tons, 1.2 MW) — modelled

BAC's PFI-1224N-3D2DS-L2 — a PFi closed-circuit cooler, 265 nominal tons (1165 kW): rated to cool 798 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 74.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 874–1457 kW · EU
‹ Previous1…4041424344…140Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers