Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 26Systems 3346Components 10248
All categoriesCooling tower / heat rejection 3307VRF / multi-split 8Air handler 7Plant / central 5Fan coil / terminal 4Condensing unit 3Rooftop / packaged 3Split system 3Chiller 2Heat recovery / DOAS 2Evaporative air cooler 1Unit cooler / refrigeration 1
All manufacturersBaltimore Aircoil 1900EVAPCO 1408Midea 2Gree 1Hitachi 1Samsung 1
All seriesAT 992ATWB 416PFi 359PCC 214Series 3000 189Series 1500 173Series V closed circuit 173Vertex VRC 157VCA 151Series V 122CXVB 118FXV 100PT2 46CXVT 40Series V EC 26FXT 20Nexus 12DVM S 1GMV5 1Set Free FSXN 1V4+ 1V6 1
Any capacity500 kW and up 3088100–500 kW 39125–100 kW 76up to 25 kW 25
Any certificationCTI STD-201 (validation C13A-99R28) 822CTI STD-201 (validation C13F-09R12) 416CTI STD-201 (validation C11F-92R20) 362CTI STD-201 (validation C11K-00R03) 153CTI STD-201 (validation C11J-98R12) 100CTI STD-201 (validation C11B-92R07) 90CTI STD-201 (validation C11L-07R05) 46CTI STD-201 (validation C11Q-18R02) 2
All marketsEU 3346
All tagsexample 3346
All suppliersHVAC Builder 3345Aeronim Systems (fictional) 1
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 1057–1080 of 3346

Baltimore Aircoil PFI-0709N-6D2ES-L1 closed-circuit cooler (93 tons, 407 kW) — modelled

BAC's PFI-0709N-6D2ES-L1 — a PFi closed-circuit cooler, 93 nominal tons (407 kW): rated to cool 279 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 17.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 306–509 kW · EU

Baltimore Aircoil PFI-1024N-3D2DS-K2 closed-circuit cooler (206 tons, 907 kW) — modelled

BAC's PFI-1024N-3D2DS-K2 — a PFi closed-circuit cooler, 206 nominal tons (907 kW): rated to cool 621 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 56.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 680–1134 kW · EU

Baltimore Aircoil PFI-1218N-2D4ES-N1 closed-circuit cooler (193 tons, 850 kW) — modelled

BAC's PFI-1218N-2D4ES-N1 — a PFi closed-circuit cooler, 193 nominal tons (850 kW): rated to cool 582 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 56.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 637–1062 kW · EU

Baltimore Aircoil PFI-1224N-6D1ES-O2 closed-circuit cooler (434 tons, 1.9 MW) — modelled

BAC's PFI-1224N-6D1ES-O2 — a PFi closed-circuit cooler, 434 nominal tons (1906 kW): rated to cool 1305 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 82.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1429–2382 kW · EU

Baltimore Aircoil PFI-0718N-2D1DS-H2 closed-circuit cooler (91 tons, 399 kW) — modelled

BAC's PFI-0718N-2D1DS-H2 — a PFi closed-circuit cooler, 91 nominal tons (399 kW): rated to cool 273 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 32.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 299–498 kW · EU

Baltimore Aircoil PFI-1024N-3D2ES-L2 closed-circuit cooler (242 tons, 1.1 MW) — modelled

BAC's PFI-1024N-3D2ES-L2 — a PFi closed-circuit cooler, 242 nominal tons (1065 kW): rated to cool 729 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 61.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 799–1331 kW · EU

Baltimore Aircoil PFI-1218N-3D1DS-L1 closed-circuit cooler (191 tons, 841 kW) — modelled

BAC's PFI-1218N-3D1DS-L1 — a PFi closed-circuit cooler, 191 nominal tons (841 kW): rated to cool 576 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 50.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 631–1052 kW · EU

Baltimore Aircoil PFI-1236N-2D1DS-N2 closed-circuit cooler (331 tons, 1.5 MW) — modelled

BAC's PFI-1236N-2D1DS-N2 — a PFi closed-circuit cooler, 331 nominal tons (1455 kW): rated to cool 996 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 126.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1091–1818 kW · EU

Baltimore Aircoil PFI-0718N-2D4ES-J2 closed-circuit cooler (113 tons, 495 kW) — modelled

BAC's PFI-0718N-2D4ES-J2 — a PFi closed-circuit cooler, 113 nominal tons (495 kW): rated to cool 339 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 32.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 371–619 kW · EU

Baltimore Aircoil PFI-1024N-3D2ES-M2 closed-circuit cooler (256 tons, 1.1 MW) — modelled

BAC's PFI-1024N-3D2ES-M2 — a PFi closed-circuit cooler, 256 nominal tons (1126 kW): rated to cool 771 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 67.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 845–1408 kW · EU

Baltimore Aircoil PFI-1218N-3D1DS-O1 closed-circuit cooler (219 tons, 964 kW) — modelled

BAC's PFI-1218N-3D1DS-O1 — a PFi closed-circuit cooler, 219 nominal tons (964 kW): rated to cool 660 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 63.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 723–1205 kW · EU

Baltimore Aircoil PFI-1236N-2D2DS-N2 closed-circuit cooler (343 tons, 1.5 MW) — modelled

BAC's PFI-1236N-2D2DS-N2 — a PFi closed-circuit cooler, 343 nominal tons (1507 kW): rated to cool 1032 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 122.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1130–1884 kW · EU

Baltimore Aircoil PFI-0718N-3D1DS-H2 closed-circuit cooler (115 tons, 504 kW) — modelled

BAC's PFI-0718N-3D1DS-H2 — a PFi closed-circuit cooler, 115 nominal tons (504 kW): rated to cool 345 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 30.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 378–630 kW · EU

Baltimore Aircoil PFI-1024N-3D4DS-L2 closed-circuit cooler (235 tons, 1.0 MW) — modelled

BAC's PFI-1024N-3D4DS-L2 — a PFi closed-circuit cooler, 235 nominal tons (1034 kW): rated to cool 708 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 60.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 776–1293 kW · EU

Baltimore Aircoil PFI-1218N-3D2DS-M1 closed-circuit cooler (208 tons, 916 kW) — modelled

BAC's PFI-1218N-3D2DS-M1 — a PFi closed-circuit cooler, 208 nominal tons (916 kW): rated to cool 627 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 54.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 687–1145 kW · EU

Baltimore Aircoil PFI-1236N-2D2ES-M2 closed-circuit cooler (353 tons, 1.6 MW) — modelled

BAC's PFI-1236N-2D2ES-M2 — a PFi closed-circuit cooler, 353 nominal tons (1551 kW): rated to cool 1062 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 109.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1163–1939 kW · EU

Baltimore Aircoil PFI-0718N-3D1DS-J2 closed-circuit cooler (124 tons, 543 kW) — modelled

BAC's PFI-0718N-3D1DS-J2 — a PFi closed-circuit cooler, 124 nominal tons (543 kW): rated to cool 372 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 34.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 407–679 kW · EU

Baltimore Aircoil PFI-1024N-4D1DS-J2 closed-circuit cooler (216 tons, 951 kW) — modelled

BAC's PFI-1024N-4D1DS-J2 — a PFi closed-circuit cooler, 216 nominal tons (951 kW): rated to cool 651 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 50.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 713–1188 kW · EU

Baltimore Aircoil PFI-1218N-3D2ES-P1 closed-circuit cooler (260 tons, 1.1 MW) — modelled

BAC's PFI-1218N-3D2ES-P1 — a PFi closed-circuit cooler, 260 nominal tons (1144 kW): rated to cool 783 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 64.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 858–1429 kW · EU

Baltimore Aircoil PFI-1236N-2D3DS-K2 closed-circuit cooler (296 tons, 1.3 MW) — modelled

BAC's PFI-1236N-2D3DS-K2 — a PFi closed-circuit cooler, 296 nominal tons (1301 kW): rated to cool 891 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 88.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 976–1627 kW · EU

Baltimore Aircoil PFI-0718N-3D2DS-J2 closed-circuit cooler (128 tons, 561 kW) — modelled

BAC's PFI-0718N-3D2DS-J2 — a PFi closed-circuit cooler, 128 nominal tons (561 kW): rated to cool 384 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 34.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 421–701 kW · EU

Baltimore Aircoil PFI-1024N-4D1DS-M2 closed-circuit cooler (266 tons, 1.2 MW) — modelled

BAC's PFI-1024N-4D1DS-M2 — a PFi closed-circuit cooler, 266 nominal tons (1170 kW): rated to cool 801 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 69.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 877–1462 kW · EU

Baltimore Aircoil PFI-1218N-3D3DS-L1 closed-circuit cooler (198 tons, 872 kW) — modelled

BAC's PFI-1218N-3D3DS-L1 — a PFi closed-circuit cooler, 198 nominal tons (872 kW): rated to cool 597 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 47.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 654–1090 kW · EU

Baltimore Aircoil PFI-1236N-2D4ES-K2 closed-circuit cooler (319 tons, 1.4 MW) — modelled

BAC's PFI-1236N-2D4ES-K2 — a PFi closed-circuit cooler, 319 nominal tons (1402 kW): rated to cool 960 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 83.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1052–1753 kW · EU
‹ Previous1…4344454647…140Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers