| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 19-3H11 cooling tower (201 tons, 885 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3H11 — an AT cooling tower, 201 nominal tons (885 kW): rated to cool 606 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 664–1106 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-5D1ES-M1 closed-circuit cooler (91 tons, 399 kW) — modelled Example modelled from published data BAC's PFI-0709N-5D1ES-M1 — a PFi closed-circuit cooler, 91 nominal tons (399 kW): rated to cool 273 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 20.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 299–498 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4K14 closed-circuit cooler (557 tons, 2.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4K14 — an ATWB closed-circuit cooler, 557 nominal tons (2448 kW): rated to cool 1397 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 81.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1836–3061 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-1012A-5P cooling tower (449 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-1012A-5P — a PT2 cooling tower, 449 nominal tons (1972 kW): rated to cool 1350 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 41.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1479–2465 kW | EU | Open in the builder |
| EVAPCO AT 19-3H12 cooling tower (228 tons, 1.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3H12 — an AT cooling tower, 228 nominal tons (1003 kW): rated to cool 687 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 23.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 753–1254 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-12LC-2 cooling tower (855 tons, 3.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-12LC-2 — a Series 1500 cooling tower, 855 nominal tons (3759 kW): rated to cool 2574 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 90.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2819–4699 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4K18 closed-circuit cooler (691 tons, 3.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4K18 — an ATWB closed-circuit cooler, 691 nominal tons (3039 kW): rated to cool 1734 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 99.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2279–3799 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-10Q-2 cooling tower (1616 tons, 7.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-10Q-2 — a Series 3000 cooling tower, 1616 nominal tons (7102 kW): rated to cool 4863 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 181.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5327–8878 kW | EU | Open in the builder |
| EVAPCO AT 19-3H14 cooling tower (248 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3H14 — an AT cooling tower, 248 nominal tons (1091 kW): rated to cool 747 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 26.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 818–1364 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-507-O cooling tower (505 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓ BAC's VT1-507-O — a Series V cooling tower, 505 nominal tons (2221 kW): rated to cool 1521 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 58.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1666–2777 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4K28 closed-circuit cooler (1064 tons, 4.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4K28 — an ATWB closed-circuit cooler, 1064 nominal tons (4679 kW): rated to cool 2670 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 162.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3509–5848 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-036-51L closed-circuit cooler (49 tons, 215 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-036-51L — a Series V closed circuit closed-circuit cooler, 49 nominal tons (215 kW): rated to cool 147 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 11.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 161–268 kW | EU | Open in the builder |
| EVAPCO AT 19-3H6 cooling tower (138 tons, 605 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3H6 — an AT cooling tower, 138 nominal tons (605 kW): rated to cool 414 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 14.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 453–756 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-161A evaporative condenser (694 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-161A — a VCA evaporative condenser rejecting 694 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 14.7 m³/s of the maker's own printed air, with a 7.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 520–867 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4L12 closed-circuit cooler (526 tons, 2.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4L12 — an ATWB closed-circuit cooler, 526 nominal tons (2310 kW): rated to cool 1318 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 77.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1733–2888 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0364B-1012N-LA evaporative condenser (2.2 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0364B-1012N-LA — a Vertex VRC evaporative condenser rejecting 2206 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 33.9 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1654–2757 kW | EU | Open in the builder |
| EVAPCO AT 19-3H8 cooling tower (164 tons, 723 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3H8 — an AT cooling tower, 164 nominal tons (723 kW): rated to cool 495 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 542–904 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-227-0812-20 evaporative condenser (1.4 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-227-0812-20 — a CXVB evaporative condenser rejecting 1375 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 34.1 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1032–1719 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4L14 closed-circuit cooler (601 tons, 2.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4L14 — an ATWB closed-circuit cooler, 601 nominal tons (2642 kW): rated to cool 1508 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 87.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1981–3302 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-843-1224-60 evaporative condenser (5.1 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-843-1224-60 — a CXVT evaporative condenser rejecting 5124 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 98.1 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 3843–6405 kW | EU | Open in the builder |
| EVAPCO AT 19-3H9 cooling tower (180 tons, 793 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3H9 — an AT cooling tower, 180 nominal tons (793 kW): rated to cool 543 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 18.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 595–991 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0812B-23Q-O closed-circuit cooler (152 tons, 670 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0812B-23Q-O — an FXV closed-circuit cooler, 152 nominal tons (670 kW): rated to cool 459 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 38.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 503–838 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4L18 closed-circuit cooler (745 tons, 3.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4L18 — an ATWB closed-circuit cooler, 745 nominal tons (3275 kW): rated to cool 1869 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 106.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2456–4094 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0295-1012N030 evaporative condenser (1.8 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0295-1012N030 — a PCC evaporative condenser rejecting 1792 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 37.3 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1344–2240 kW | EU | Open in the builder |