Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 1,129–1,152 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 19-3J11 cooling tower (255 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3J11 — an AT cooling tower, 255 nominal tons (1122 kW): rated to cool 768 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 26.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 841–1402 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-5D3ES-L1 closed-circuit cooler (88 tons, 386 kW) — modelled Example modelled from published data BAC's PFI-0709N-5D3ES-L1 — a PFi closed-circuit cooler, 88 nominal tons (386 kW): rated to cool 264 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 17.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 289–482 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4M28 closed-circuit cooler (1222 tons, 5.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4M28 — an ATWB closed-circuit cooler, 1222 nominal tons (5374 kW): rated to cool 3066 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 183.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4030–6717 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-1212A-2O cooling tower (435 tons, 1.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-1212A-2O — a PT2 cooling tower, 435 nominal tons (1910 kW): rated to cool 1308 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 48.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1433–2388 kW | EU | Open in the builder |
| EVAPCO AT 19-3J12 cooling tower (288 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3J12 — an AT cooling tower, 288 nominal tons (1266 kW): rated to cool 867 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 29.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 950–1583 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-12LN-2 cooling tower (895 tons, 3.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-12LN-2 — a Series 1500 cooling tower, 895 nominal tons (3934 kW): rated to cool 2694 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 95.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2951–4918 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4N12 closed-circuit cooler (616 tons, 2.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4N12 — an ATWB closed-circuit cooler, 616 nominal tons (2709 kW): rated to cool 1546 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 88.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2032–3386 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-10R-2 cooling tower (1706 tons, 7.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-10R-2 — a Series 3000 cooling tower, 1706 nominal tons (7501 kW): rated to cool 5136 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 191.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5626–9376 kW | EU | Open in the builder |
| EVAPCO AT 19-3J14 cooling tower (314 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3J14 — an AT cooling tower, 314 nominal tons (1380 kW): rated to cool 945 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 32.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1035–1725 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-560-O cooling tower (558 tons, 2.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓ BAC's VT1-560-O — a Series V cooling tower, 558 nominal tons (2454 kW): rated to cool 1680 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 56.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1840–3067 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4N14 closed-circuit cooler (703 tons, 3.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4N14 — an ATWB closed-circuit cooler, 703 nominal tons (3093 kW): rated to cool 1765 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 99.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2319–3866 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-048-21M closed-circuit cooler (55 tons, 241 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-048-21M — a Series V closed circuit closed-circuit cooler, 55 nominal tons (241 kW): rated to cool 165 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 16.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 181–301 kW | EU | Open in the builder |
| EVAPCO AT 19-3J8 cooling tower (196 tons, 863 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3J8 — an AT cooling tower, 196 nominal tons (863 kW): rated to cool 591 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 647–1079 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-170A evaporative condenser (732 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-170A — a VCA evaporative condenser rejecting 732 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 13.2 m³/s of the maker's own printed air, with a 5.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 549–915 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4N18 closed-circuit cooler (870 tons, 3.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4N18 — an ATWB closed-circuit cooler, 870 nominal tons (3825 kW): rated to cool 2182 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 123.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2869–4781 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0378B-1212N-HB evaporative condenser (2.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0378B-1212N-HB — a Vertex VRC evaporative condenser rejecting 2292 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 36.4 m³/s of the maker's own printed air, with a 19.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1719–2864 kW | EU | Open in the builder |
| EVAPCO AT 19-3J9 cooling tower (231 tons, 1.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3J9 — an AT cooling tower, 231 nominal tons (1016 kW): rated to cool 696 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 23.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 762–1271 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-237-1212-10 evaporative condenser (1.4 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-237-1212-10 — a CXVB evaporative condenser rejecting 1436 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 33.9 m³/s of the maker's own printed air, with a 7.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1077–1795 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4N20 closed-circuit cooler (936 tons, 4.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4N20 — an ATWB closed-circuit cooler, 936 nominal tons (4116 kW): rated to cool 2349 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 132.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3087–5145 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-887-1224-60 evaporative condenser (5.4 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-887-1224-60 — a CXVT evaporative condenser rejecting 5388 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 95.9 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 4041–6736 kW | EU | Open in the builder |
| EVAPCO AT 19-3K11 cooling tower (284 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-3K11 — an AT cooling tower, 284 nominal tons (1249 kW): rated to cool 855 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 937–1561 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0812B-24T-O closed-circuit cooler (177 tons, 780 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0812B-24T-O — an FXV closed-circuit cooler, 177 nominal tons (780 kW): rated to cool 534 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 38.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 585–975 kW | EU | Open in the builder |
| EVAPCO ATWB 24-4O18 closed-circuit cooler (936 tons, 4.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-4O18 — an ATWB closed-circuit cooler, 936 nominal tons (4113 kW): rated to cool 2347 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 130.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3085–5141 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0309-1212N020 evaporative condenser (1.9 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0309-1212N020 — a PCC evaporative condenser rejecting 1877 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 36.0 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1408–2346 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers