Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 26Systems 3346Components 10248
All categoriesCooling tower / heat rejection 3307VRF / multi-split 8Air handler 7Plant / central 5Fan coil / terminal 4Condensing unit 3Rooftop / packaged 3Split system 3Chiller 2Heat recovery / DOAS 2Evaporative air cooler 1Unit cooler / refrigeration 1
All manufacturersBaltimore Aircoil 1900EVAPCO 1408Midea 2Gree 1Hitachi 1Samsung 1
All seriesAT 992ATWB 416PFi 359PCC 214Series 3000 189Series 1500 173Series V closed circuit 173Vertex VRC 157VCA 151Series V 122CXVB 118FXV 100PT2 46CXVT 40Series V EC 26FXT 20Nexus 12DVM S 1GMV5 1Set Free FSXN 1V4+ 1V6 1
Any capacity500 kW and up 3088100–500 kW 39125–100 kW 76up to 25 kW 25
Any certificationCTI STD-201 (validation C13A-99R28) 822CTI STD-201 (validation C13F-09R12) 416CTI STD-201 (validation C11F-92R20) 362CTI STD-201 (validation C11K-00R03) 153CTI STD-201 (validation C11J-98R12) 100CTI STD-201 (validation C11B-92R07) 90CTI STD-201 (validation C11L-07R05) 46CTI STD-201 (validation C11Q-18R02) 2
All marketsEU 3346
All tagsexample 3346
All suppliersHVAC Builder 3345Aeronim Systems (fictional) 1
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 1177–1200 of 3346

Baltimore Aircoil PFI-2412N-6D1ES-O2 closed-circuit cooler (434 tons, 1.9 MW) — modelled

BAC's PFI-2412N-6D1ES-O2 — a PFi closed-circuit cooler, 434 nominal tons (1906 kW): rated to cool 1305 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 82.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1429–2382 kW · EU

Baltimore Aircoil PFI-2418N-4D4DS-O2 closed-circuit cooler (527 tons, 2.3 MW) — modelled

BAC's PFI-2418N-4D4DS-O2 — a PFi closed-circuit cooler, 527 nominal tons (2318 kW): rated to cool 1587 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 108.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1738–2897 kW · EU

Baltimore Aircoil PFI-2012N-4D1ES-J2 closed-circuit cooler (235 tons, 1.0 MW) — modelled

BAC's PFI-2012N-4D1ES-J2 — a PFi closed-circuit cooler, 235 nominal tons (1034 kW): rated to cool 708 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 49.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 776–1293 kW · EU

Baltimore Aircoil PFI-2418N-2D1DS-N2 closed-circuit cooler (331 tons, 1.5 MW) — modelled

BAC's PFI-2418N-2D1DS-N2 — a PFi closed-circuit cooler, 331 nominal tons (1455 kW): rated to cool 996 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 126.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1091–1818 kW · EU

Baltimore Aircoil PFI-2418N-4D4DS-P2 closed-circuit cooler (569 tons, 2.5 MW) — modelled

BAC's PFI-2418N-4D4DS-P2 — a PFi closed-circuit cooler, 569 nominal tons (2502 kW): rated to cool 1713 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 118.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1876–3127 kW · EU

Baltimore Aircoil PFI-2012N-4D1ES-M2 closed-circuit cooler (289 tons, 1.3 MW) — modelled

BAC's PFI-2012N-4D1ES-M2 — a PFi closed-circuit cooler, 289 nominal tons (1271 kW): rated to cool 870 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 67.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 953–1588 kW · EU

Baltimore Aircoil PFI-2418N-2D2DS-N2 closed-circuit cooler (343 tons, 1.5 MW) — modelled

BAC's PFI-2418N-2D2DS-N2 — a PFi closed-circuit cooler, 343 nominal tons (1507 kW): rated to cool 1032 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 122.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1130–1884 kW · EU

Baltimore Aircoil PFI-2418N-4D4ES-Q2 closed-circuit cooler (637 tons, 2.8 MW) — modelled

BAC's PFI-2418N-4D4ES-Q2 — a PFi closed-circuit cooler, 637 nominal tons (2800 kW): rated to cool 1917 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 123.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 2100–3500 kW · EU

Baltimore Aircoil PFI-2012N-4D3ES-L2 closed-circuit cooler (283 tons, 1.2 MW) — modelled

BAC's PFI-2012N-4D3ES-L2 — a PFi closed-circuit cooler, 283 nominal tons (1244 kW): rated to cool 852 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 57.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 933–1555 kW · EU

Baltimore Aircoil PFI-2418N-2D2ES-M2 closed-circuit cooler (353 tons, 1.6 MW) — modelled

BAC's PFI-2418N-2D2ES-M2 — a PFi closed-circuit cooler, 353 nominal tons (1551 kW): rated to cool 1062 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 109.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 1163–1939 kW · EU

Baltimore Aircoil PFI-2418N-5D2ES-Q2 closed-circuit cooler (658 tons, 2.9 MW) — modelled

BAC's PFI-2418N-5D2ES-Q2 — a PFi closed-circuit cooler, 658 nominal tons (2892 kW): rated to cool 1980 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 127.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published data
Cooling tower / heat rejection · 2169–3615 kW · EU

Baltimore Aircoil PT2-0412A-1H cooling tower (122 tons, 535 kW) — modelled

BAC's PT2-0412A-1H — a PT2 cooling tower, 122 nominal tons (535 kW): rated to cool 366 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 401–668 kW · EU

Baltimore Aircoil PT2-0412A-2J cooling tower (153 tons, 675 kW) — modelled

BAC's PT2-0412A-2J — a PT2 cooling tower, 153 nominal tons (675 kW): rated to cool 462 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 506–843 kW · EU

Baltimore Aircoil PT2-0412A-3J cooling tower (157 tons, 692 kW) — modelled

BAC's PT2-0412A-3J — a PT2 cooling tower, 157 nominal tons (692 kW): rated to cool 474 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 519–865 kW · EU

Baltimore Aircoil PT2-0412A-4J cooling tower (163 tons, 719 kW) — modelled

BAC's PT2-0412A-4J — a PT2 cooling tower, 163 nominal tons (719 kW): rated to cool 492 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 539–898 kW · EU

Baltimore Aircoil PT2-0709A-1K cooling tower (158 tons, 697 kW) — modelled

BAC's PT2-0709A-1K — a PT2 cooling tower, 158 nominal tons (697 kW): rated to cool 477 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 522–871 kW · EU

Baltimore Aircoil PT2-0709A-2L cooling tower (198 tons, 872 kW) — modelled

BAC's PT2-0709A-2L — a PT2 cooling tower, 198 nominal tons (872 kW): rated to cool 597 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 22.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 654–1090 kW · EU

Baltimore Aircoil PT2-0709A-3L cooling tower (209 tons, 920 kW) — modelled

BAC's PT2-0709A-3L — a PT2 cooling tower, 209 nominal tons (920 kW): rated to cool 630 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 690–1150 kW · EU

Baltimore Aircoil PT2-0709A-4L cooling tower (213 tons, 938 kW) — modelled

BAC's PT2-0709A-4L — a PT2 cooling tower, 213 nominal tons (938 kW): rated to cool 642 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 703–1172 kW · EU

Baltimore Aircoil PT2-0709A-5L cooling tower (222 tons, 977 kW) — modelled

BAC's PT2-0709A-5L — a PT2 cooling tower, 222 nominal tons (977 kW): rated to cool 669 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 733–1221 kW · EU

Baltimore Aircoil PT2-0809A-1L cooling tower (197 tons, 868 kW) — modelled

BAC's PT2-0809A-1L — a PT2 cooling tower, 197 nominal tons (868 kW): rated to cool 594 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 26.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 651–1084 kW · EU

Baltimore Aircoil PT2-0809A-2L cooling tower (223 tons, 981 kW) — modelled

BAC's PT2-0809A-2L — a PT2 cooling tower, 223 nominal tons (981 kW): rated to cool 672 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 24.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 736–1227 kW · EU

Baltimore Aircoil PT2-0809A-3M cooling tower (257 tons, 1.1 MW) — modelled

BAC's PT2-0809A-3M — a PT2 cooling tower, 257 nominal tons (1130 kW): rated to cool 774 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 25.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 848–1413 kW · EU

Baltimore Aircoil PT2-0809A-4M cooling tower (263 tons, 1.2 MW) — modelled

BAC's PT2-0809A-4M — a PT2 cooling tower, 263 nominal tons (1157 kW): rated to cool 792 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 25.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C11L-07R05) ✓
Cooling tower / heat rejection · 868–1446 kW · EU