Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 1,177–1,200 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 19-4F8 cooling tower (133 tons, 583 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-4F8 — an AT cooling tower, 133 nominal tons (583 kW): rated to cool 399 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 12.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 437–728 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-6D1ES-K1 closed-circuit cooler (85 tons, 372 kW) — modelled Example modelled from published data BAC's PFI-0709N-6D1ES-K1 — a PFi closed-circuit cooler, 85 nominal tons (372 kW): rated to cool 255 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 16.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 279–466 kW | EU | Open in the builder |
| EVAPCO ATWB 24-5M12 closed-circuit cooler (617 tons, 2.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-5M12 — an ATWB closed-circuit cooler, 617 nominal tons (2713 kW): rated to cool 1548 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 79.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2035–3391 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-1212A-4P cooling tower (510 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-1212A-4P — a PT2 cooling tower, 510 nominal tons (2243 kW): rated to cool 1536 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 50.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1682–2804 kW | EU | Open in the builder |
| EVAPCO AT 19-4G11 cooling tower (189 tons, 832 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-4G11 — an AT cooling tower, 189 nominal tons (832 kW): rated to cool 570 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 18.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 624–1041 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-12MN-2 cooling tower (987 tons, 4.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-12MN-2 — a Series 1500 cooling tower, 987 nominal tons (4338 kW): rated to cool 2970 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 104.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3253–5422 kW | EU | Open in the builder |
| EVAPCO ATWB 24-5M14 closed-circuit cooler (696 tons, 3.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-5M14 — an ATWB closed-circuit cooler, 696 nominal tons (3060 kW): rated to cool 1746 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 88.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2295–3825 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-10S-2 cooling tower (1826 tons, 8.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-10S-2 — a Series 3000 cooling tower, 1826 nominal tons (8027 kW): rated to cool 5496 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 204.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 6020–10033 kW | EU | Open in the builder |
| EVAPCO AT 19-4G6 cooling tower (130 tons, 570 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-4G6 — an AT cooling tower, 130 nominal tons (570 kW): rated to cool 390 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 12.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 427–712 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-750-P cooling tower (748 tons, 3.3 MW) — modelled Example modelled from published data BAC's VT1-750-P — a Series V cooling tower, 748 nominal tons (3286 kW): rated to cool 2250 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 74.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2465–4108 kW | EU | Open in the builder |
| EVAPCO ATWB 24-5M18 closed-circuit cooler (847 tons, 3.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-5M18 — an ATWB closed-circuit cooler, 847 nominal tons (3724 kW): rated to cool 2125 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 109.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2793–4655 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-048-31N closed-circuit cooler (65 tons, 285 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-048-31N — a Series V closed circuit closed-circuit cooler, 65 nominal tons (285 kW): rated to cool 195 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 18.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 214–356 kW | EU | Open in the builder |
| EVAPCO AT 19-4G8 cooling tower (158 tons, 697 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-4G8 — an AT cooling tower, 158 nominal tons (697 kW): rated to cool 477 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 14.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 522–871 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-1774A evaporative condenser (7.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-1774A — a VCA evaporative condenser rejecting 7643 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 127.0 m³/s of the maker's own printed air, with a 89.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 5732–9553 kW | EU | Open in the builder |
| EVAPCO ATWB 24-5M20 closed-circuit cooler (907 tons, 4.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-5M20 — an ATWB closed-circuit cooler, 907 nominal tons (3985 kW): rated to cool 2274 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 117.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2989–4982 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0383B-1012N-JB evaporative condenser (2.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0383B-1012N-JB — a Vertex VRC evaporative condenser rejecting 2323 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 35.3 m³/s of the maker's own printed air, with a 30.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1742–2903 kW | EU | Open in the builder |
| EVAPCO AT 19-4G9 cooling tower (164 tons, 723 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-4G9 — an AT cooling tower, 164 nominal tons (723 kW): rated to cool 495 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 542–904 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-241-0812-10 evaporative condenser (1.5 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-241-0812-10 — a CXVB evaporative condenser rejecting 1460 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 26.4 m³/s of the maker's own printed air, with a 7.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1095–1825 kW | EU | Open in the builder |
| EVAPCO ATWB 24-5M28 closed-circuit cooler (1333 tons, 5.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-5M28 — an ATWB closed-circuit cooler, 1333 nominal tons (5858 kW): rated to cool 3343 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 177.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4393–7322 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-933-1426-50 evaporative condenser (5.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-933-1426-50 — a CXVT evaporative condenser rejecting 5667 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 100.3 m³/s of the maker's own printed air, with a 37.3 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 4250–7084 kW | EU | Open in the builder |
| EVAPCO AT 19-4H11 cooling tower (219 tons, 964 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 19-4H11 — an AT cooling tower, 219 nominal tons (964 kW): rated to cool 660 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 723–1205 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0812B-30T-O closed-circuit cooler (190 tons, 837 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0812B-30T-O — an FXV closed-circuit cooler, 190 nominal tons (837 kW): rated to cool 573 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 38.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 628–1046 kW | EU | Open in the builder |
| EVAPCO ATWB 24-5N12 closed-circuit cooler (679 tons, 3.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 24-5N12 — an ATWB closed-circuit cooler, 679 nominal tons (2984 kW): rated to cool 1703 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 86.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2238–3730 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0323-1012N030 evaporative condenser (2.0 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0323-1012N030 — a PCC evaporative condenser rejecting 1962 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 33.5 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1472–2453 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers