EVAPCO AT 19-3K12 cooling tower (318 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3K12 — an AT cooling tower, 318 nominal tons (1398 kW): rated to cool 957 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 32.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1048–1747 kWEUOpen in the builder
Baltimore Aircoil PFI-0709N-5D4DS-K1 closed-circuit cooler (76 tons, 333 kW) — modelled Example modelled from published data
BAC's PFI-0709N-5D4DS-K1 — a PFi closed-circuit cooler, 76 nominal tons (333 kW): rated to cool 228 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 15.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection250–416 kWEUOpen in the builder
EVAPCO ATWB 24-4O20 closed-circuit cooler (1007 tons, 4.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-4O20 — an ATWB closed-circuit cooler, 1007 nominal tons (4426 kW): rated to cool 2525 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 141.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection3319–5532 kWEUOpen in the builder
Baltimore Aircoil PT2-1212A-3P cooling tower (500 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓
BAC's PT2-1212A-3P — a PT2 cooling tower, 500 nominal tons (2199 kW): rated to cool 1506 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 49.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1650–2749 kWEUOpen in the builder
EVAPCO AT 19-3K14 cooling tower (346 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3K14 — an AT cooling tower, 346 nominal tons (1520 kW): rated to cool 1041 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 35.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1140–1900 kWEUOpen in the builder
Baltimore Aircoil Series 1500 S15E-1212-12MN cooling tower (493 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S15E-1212-12MN — a Series 1500 cooling tower, 493 nominal tons (2169 kW): rated to cool 1485 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 52.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1627–2711 kWEUOpen in the builder
EVAPCO ATWB 24-5K12 closed-circuit cooler (539 tons, 2.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-5K12 — an ATWB closed-circuit cooler, 539 nominal tons (2368 kW): rated to cool 1351 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 70.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1776–2960 kWEUOpen in the builder
Baltimore Aircoil Series 3000 S3E-1222-10S cooling tower (913 tons, 4.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S3E-1222-10S — a Series 3000 cooling tower, 913 nominal tons (4013 kW): rated to cool 2748 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 102.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection3010–5017 kWEUOpen in the builder
EVAPCO AT 19-3L12 cooling tower (339 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3L12 — an AT cooling tower, 339 nominal tons (1490 kW): rated to cool 1020 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 34.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1117–1862 kWEUOpen in the builder
Baltimore Aircoil Series V VT1-680-P cooling tower (678 tons, 3.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓
BAC's VT1-680-P — a Series V cooling tower, 678 nominal tons (2979 kW): rated to cool 2040 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 77.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2235–3724 kWEUOpen in the builder
EVAPCO ATWB 24-5L12 closed-circuit cooler (581 tons, 2.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-5L12 — an ATWB closed-circuit cooler, 581 nominal tons (2553 kW): rated to cool 1457 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 75.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1915–3191 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-048-31M closed-circuit cooler (59 tons, 259 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓
BAC's VF1-048-31M — a Series V closed circuit closed-circuit cooler, 59 nominal tons (259 kW): rated to cool 177 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 16.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection194–323 kWEUOpen in the builder
EVAPCO AT 19-3L14 cooling tower (376 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3L14 — an AT cooling tower, 376 nominal tons (1652 kW): rated to cool 1131 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 37.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1239–2065 kWEUOpen in the builder
Baltimore Aircoil VCA-174A evaporative condenser (750 kW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-174A — a VCA evaporative condenser rejecting 750 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 14.8 m³/s of the maker's own printed air, with a 3.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection562–937 kWEUOpen in the builder
EVAPCO ATWB 24-5L14 closed-circuit cooler (655 tons, 2.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-5L14 — an ATWB closed-circuit cooler, 655 nominal tons (2881 kW): rated to cool 1644 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 84.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2161–3601 kWEUOpen in the builder
Baltimore Aircoil VRC-0381B-1212N-KA evaporative condenser (2.3 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0381B-1212N-KA — a Vertex VRC evaporative condenser rejecting 2314 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 31.8 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1735–2892 kWEUOpen in the builder
EVAPCO AT 19-3M14 cooling tower (398 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3M14 — an AT cooling tower, 398 nominal tons (1748 kW): rated to cool 1197 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1311–2185 kWEUOpen in the builder
Baltimore Aircoil CXVB-238-0812-15 evaporative condenser (1.4 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVB-238-0812-15 — a CXVB evaporative condenser rejecting 1442 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 30.8 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1081–1802 kWEUOpen in the builder
EVAPCO ATWB 24-5L18 closed-circuit cooler (798 tons, 3.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-5L18 — an ATWB closed-circuit cooler, 798 nominal tons (3508 kW): rated to cool 2002 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 103.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2631–4386 kWEUOpen in the builder
Baltimore Aircoil CXVT-894-1426-50 evaporative condenser (5.4 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVT-894-1426-50 — a CXVT evaporative condenser rejecting 5428 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 100.3 m³/s of the maker's own printed air, with a 37.3 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection4071–6785 kWEUOpen in the builder
EVAPCO AT 19-4F6 cooling tower (109 tons, 478 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-4F6 — an AT cooling tower, 109 nominal tons (478 kW): rated to cool 327 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 10.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection358–597 kWEUOpen in the builder
Baltimore Aircoil FXV-0812B-28D-K closed-circuit cooler (148 tons, 648 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓
BAC's FXV-0812B-28D-K — an FXV closed-circuit cooler, 148 nominal tons (648 kW): rated to cool 444 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 26.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection486–811 kWEUOpen in the builder
EVAPCO ATWB 24-5L28 closed-circuit cooler (1254 tons, 5.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-5L28 — an ATWB closed-circuit cooler, 1254 nominal tons (5513 kW): rated to cool 3146 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 169.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection4135–6891 kWEUOpen in the builder
Baltimore Aircoil PCC-0315-1012N040 evaporative condenser (1.9 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0315-1012N040 — a PCC evaporative condenser rejecting 1913 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 43.8 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1435–2392 kWEUOpen in the builder