Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 1,105–1,128 of 3,474

NameCompanyCategoryCapacityMarketsOpen in the builder
EVAPCO AT 19-3I11 cooling tower (220 tons, 968 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3I11 — an AT cooling tower, 220 nominal tons (968 kW): rated to cool 663 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 23.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection726–1210 kWEUOpen in the builder
Baltimore Aircoil PFI-0709N-5D2DS-M1 closed-circuit cooler (88 tons, 386 kW) — modelled Example modelled from published data
BAC's PFI-0709N-5D2DS-M1 — a PFi closed-circuit cooler, 88 nominal tons (386 kW): rated to cool 264 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 20.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection289–482 kWEUOpen in the builder
EVAPCO ATWB 24-4L20 closed-circuit cooler (802 tons, 3.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-4L20 — an ATWB closed-circuit cooler, 802 nominal tons (3527 kW): rated to cool 2012 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 114.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2645–4408 kWEUOpen in the builder
Baltimore Aircoil PT2-1212A-1O cooling tower (381 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓
BAC's PT2-1212A-1O — a PT2 cooling tower, 381 nominal tons (1674 kW): rated to cool 1146 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 50.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1255–2092 kWEUOpen in the builder
EVAPCO AT 19-3I12 cooling tower (255 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3I12 — an AT cooling tower, 255 nominal tons (1122 kW): rated to cool 768 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 25.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection841–1402 kWEUOpen in the builder
Baltimore Aircoil Series 1500 S15E-1212-12LN cooling tower (448 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S15E-1212-12LN — a Series 1500 cooling tower, 448 nominal tons (1967 kW): rated to cool 1347 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 48.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1475–2459 kWEUOpen in the builder
EVAPCO ATWB 24-4L28 closed-circuit cooler (1149 tons, 5.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-4L28 — an ATWB closed-circuit cooler, 1149 nominal tons (5051 kW): rated to cool 2882 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 174.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection3788–6314 kWEUOpen in the builder
Baltimore Aircoil Series 3000 S3E-1222-10R cooling tower (853 tons, 3.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S3E-1222-10R — a Series 3000 cooling tower, 853 nominal tons (3750 kW): rated to cool 2568 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 95.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2813–4688 kWEUOpen in the builder
EVAPCO AT 19-3I14 cooling tower (279 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3I14 — an AT cooling tower, 279 nominal tons (1227 kW): rated to cool 840 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection920–1533 kWEUOpen in the builder
Baltimore Aircoil Series V VT1-550-P cooling tower (548 tons, 2.4 MW) — modelled Example modelled from published data
BAC's VT1-550-P — a Series V cooling tower, 548 nominal tons (2410 kW): rated to cool 1650 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 77.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1807–3012 kWEUOpen in the builder
EVAPCO ATWB 24-4M12 closed-circuit cooler (559 tons, 2.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-4M12 — an ATWB closed-circuit cooler, 559 nominal tons (2458 kW): rated to cool 1403 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 82.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1844–3073 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-048-21L closed-circuit cooler (48 tons, 210 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓
BAC's VF1-048-21L — a Series V closed circuit closed-circuit cooler, 48 nominal tons (210 kW): rated to cool 144 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 15.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection158–263 kWEUOpen in the builder
EVAPCO AT 19-3I6 cooling tower (150 tons, 657 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3I6 — an AT cooling tower, 150 nominal tons (657 kW): rated to cool 450 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 15.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection493–822 kWEUOpen in the builder
Baltimore Aircoil VCA-1654A evaporative condenser (7.1 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-1654A — a VCA evaporative condenser rejecting 7126 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 115.3 m³/s of the maker's own printed air, with a 67.1 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection5344–8907 kWEUOpen in the builder
EVAPCO ATWB 24-4M14 closed-circuit cooler (639 tons, 2.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-4M14 — an ATWB closed-circuit cooler, 639 nominal tons (2810 kW): rated to cool 1603 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 91.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2107–3512 kWEUOpen in the builder
Baltimore Aircoil VRC-0374B-1218N-HA evaporative condenser (2.3 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0374B-1218N-HA — a Vertex VRC evaporative condenser rejecting 2266 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 42.3 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1700–2833 kWEUOpen in the builder
EVAPCO AT 19-3I8 cooling tower (178 tons, 784 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3I8 — an AT cooling tower, 178 nominal tons (784 kW): rated to cool 537 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 18.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection588–980 kWEUOpen in the builder
Baltimore Aircoil CXVB-237-0812-10 evaporative condenser (1.4 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVB-237-0812-10 — a CXVB evaporative condenser rejecting 1436 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 26.6 m³/s of the maker's own printed air, with a 7.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1077–1795 kWEUOpen in the builder
EVAPCO ATWB 24-4M18 closed-circuit cooler (792 tons, 3.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-4M18 — an ATWB closed-circuit cooler, 792 nominal tons (3480 kW): rated to cool 1986 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 113.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2610–4350 kWEUOpen in the builder
Baltimore Aircoil CXVT-844-1426-50 evaporative condenser (5.1 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVT-844-1426-50 — a CXVT evaporative condenser rejecting 5124 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 100.8 m³/s of the maker's own printed air, with a 37.3 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection3843–6405 kWEUOpen in the builder
EVAPCO AT 19-3I9 cooling tower (198 tons, 872 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 19-3I9 — an AT cooling tower, 198 nominal tons (872 kW): rated to cool 597 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection654–1090 kWEUOpen in the builder
Baltimore Aircoil FXV-0812B-24D-L closed-circuit cooler (160 tons, 705 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓
BAC's FXV-0812B-24D-L — an FXV closed-circuit cooler, 160 nominal tons (705 kW): rated to cool 483 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 30.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection529–882 kWEUOpen in the builder
EVAPCO ATWB 24-4M20 closed-circuit cooler (852 tons, 3.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓
EVAPCO's 24-4M20 — an ATWB closed-circuit cooler, 852 nominal tons (3746 kW): rated to cool 2138 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 121.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2810–4683 kWEUOpen in the builder
Baltimore Aircoil PCC-0300-0718N040 evaporative condenser (1.8 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0300-0718N040 — a PCC evaporative condenser rejecting 1822 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 45.0 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1367–2278 kWEUOpen in the builder
‹ Previous1…4546474849…145Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers