Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 121–144 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 110-2M18 cooling tower (444 tons, 1.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 110-2M18 — an AT cooling tower, 444 nominal tons (1950 kW): rated to cool 1335 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 57.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1462–2437 kW | EU | Open in the builder |
| American Cooling Tower ACX-1023-1 cooling tower (210 tons, 924 kW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1023-1 — an ACX cooling tower, 210 nominal tons (924 kW): rated to cool 633 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 32.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 693–1156 kW | NA | Open in the builder |
| Baltimore Aircoil Nexus NXF-0403N-CS2TT-H2 closed-circuit cooler (40 tons, 175 kW) — modelled Example modelled from published data BAC's NXF-0403N-CS2TT-H2 — a Nexus closed-circuit cooler, 40 nominal tons (175 kW): rated to cool 120 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 7.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 131–219 kW | EU | Open in the builder |
| Cooling Tower Systems T-260 cooling tower (46 tons, 202 kW) — modelled Example modelled from published data CTS's T-260 — a T-2 cooling tower, 46 tons (202 kW): rated to cool 138 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 6.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one rated point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Cooling Tower Systems. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 151–252 kW | NA | Open in the builder |
| EVAPCO ATWB 10-4I36 closed-circuit cooler (488 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 10-4I36 — an ATWB closed-circuit cooler, 488 nominal tons (2146 kW): rated to cool 1224 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 67.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1609–2682 kW | EU | Open in the builder |
| American Cooling Tower ACC-86F cooling tower (108 tons, 473 kW) — modelled Example modelled from published data CTI STD-201 (validation C38E-25R00) ✓ American Cooling Tower's ACC-86F — an ACC cooling tower, 108 nominal tons (473 kW): rated to cool 324 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 355–591 kW | NA | Open in the builder |
| Baltimore Aircoil PCC-0048-0406N005 evaporative condenser (292 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0048-0406N005 — a PCC evaporative condenser rejecting 292 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 7.9 m³/s of the maker's own printed air, with a 3.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 219–365 kW | EU | Open in the builder |
| Cooling Tower Systems T-2600 cooling tower (467 tons, 2.1 MW) — modelled Example modelled from published data CTS's T-2600 — a T-2 cooling tower, 467 tons (2053 kW): rated to cool 1406 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 59.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one rated point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Cooling Tower Systems. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1540–2567 kW | NA | Open in the builder |
| EVAPCO AT 110-3I12 cooling tower (263 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 110-3I12 — an AT cooling tower, 263 nominal tons (1157 kW): rated to cool 792 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 30.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 868–1446 kW | EU | Open in the builder |
| American Cooling Tower ACX-1024-1 cooling tower (240 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1024-1 — an ACX cooling tower, 240 nominal tons (1056 kW): rated to cool 723 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 37.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 792–1320 kW | NA | Open in the builder |
| Baltimore Aircoil PFI-0406N-3D1EZ-G1 closed-circuit cooler (20 tons, 88 kW) — modelled Example modelled from published data BAC's PFI-0406N-3D1EZ-G1 — a PFi closed-circuit cooler, 20 nominal tons (88 kW): rated to cool 60 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 6.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 66–110 kW | EU | Open in the builder |
| Cooling Tower Systems T-270 cooling tower (53 tons, 234 kW) — modelled Example modelled from published data CTS's T-270 — a T-2 cooling tower, 53 tons (234 kW): rated to cool 160 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 8.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one rated point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Cooling Tower Systems. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 175–292 kW | NA | Open in the builder |
| EVAPCO ATWB 10-4J12 closed-circuit cooler (195 tons, 857 kW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 10-4J12 — an ATWB closed-circuit cooler, 195 nominal tons (857 kW): rated to cool 489 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 29.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 643–1072 kW | EU | Open in the builder |
| American Cooling Tower ACX-1025-1 cooling tower (265 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1025-1 — an ACX cooling tower, 265 nominal tons (1165 kW): rated to cool 798 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 874–1457 kW | NA | Open in the builder |
| Baltimore Aircoil PT2-0412A-2J cooling tower (153 tons, 675 kW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-0412A-2J — a PT2 cooling tower, 153 nominal tons (675 kW): rated to cool 462 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 506–843 kW | EU | Open in the builder |
| Cooling Tower Systems T-2700 cooling tower (565 tons, 2.5 MW) — modelled Example modelled from published data CTS's T-2700 — a T-2 cooling tower, 565 tons (2483 kW): rated to cool 1700 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 59.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one rated point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Cooling Tower Systems. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1862–3103 kW | NA | Open in the builder |
| EVAPCO AT 110-3I18 cooling tower (332 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 110-3I18 — an AT cooling tower, 332 nominal tons (1459 kW): rated to cool 999 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1094–1824 kW | EU | Open in the builder |
| American Cooling Tower ACX-1030-1 cooling tower (173 tons, 762 kW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1030-1 — an ACX cooling tower, 173 nominal tons (762 kW): rated to cool 522 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 22.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 572–953 kW | NA | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-07JN-2 cooling tower (562 tons, 2.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-07JN-2 — a Series 1500 cooling tower, 562 nominal tons (2471 kW): rated to cool 1692 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 62.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1853–3089 kW | EU | Open in the builder |
| Cooling Tower Systems T-28 cooling tower (6 tons, 26 kW) — modelled Example modelled from published data CTS's T-28 — a T-2 cooling tower, 6 tons (26 kW): rated to cool 18 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 1.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one rated point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Cooling Tower Systems. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 20–33 kW | NA | Open in the builder |
| EVAPCO ATWB 10-4J36 closed-circuit cooler (560 tons, 2.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 10-4J36 — an ATWB closed-circuit cooler, 560 nominal tons (2460 kW): rated to cool 1404 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 76.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1845–3075 kW | EU | Open in the builder |
| American Cooling Tower ACX-1031-1 cooling tower (205 tons, 903 kW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1031-1 — an ACX cooling tower, 205 nominal tons (903 kW): rated to cool 618 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 26.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 677–1128 kW | NA | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1020-06M-2 cooling tower (764 tons, 3.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1020-06M-2 — a Series 3000 cooling tower, 764 nominal tons (3361 kW): rated to cool 2301 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 92.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2520–4201 kW | EU | Open in the builder |
| Cooling Tower Systems T-280 cooling tower (61 tons, 270 kW) — modelled Example modelled from published data CTS's T-280 — a T-2 cooling tower, 61 tons (270 kW): rated to cool 185 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 8.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one rated point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Cooling Tower Systems. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 203–338 kW | NA | Open in the builder |