Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 169–192 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| American Cooling Tower ACX-1040-1 cooling tower (304 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1040-1 — an ACX cooling tower, 304 nominal tons (1336 kW): rated to cool 915 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 36.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1002–1670 kW | NA | Open in the builder |
| Baltimore Aircoil FXT-0506A-G cooling tower (58 tons, 254 kW) — modelled Example modelled from published data BAC's FXT-0506A-G — an FXT cooling tower, 58 nominal tons (254 kW): rated to cool 174 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 8.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 191–318 kW | EU | Open in the builder |
| EVAPCO AT 110-3L12 cooling tower (360 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 110-3L12 — an AT cooling tower, 360 nominal tons (1582 kW): rated to cool 1083 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1186–1977 kW | EU | Open in the builder |
| American Cooling Tower ACX-1041-1 cooling tower (338 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1041-1 — an ACX cooling tower, 338 nominal tons (1485 kW): rated to cool 1017 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 41.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1114–1857 kW | NA | Open in the builder |
| Baltimore Aircoil FXV-0806A-20D-K closed-circuit cooler (53 tons, 232 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0806A-20D-K — an FXV closed-circuit cooler, 53 nominal tons (232 kW): rated to cool 159 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 15.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 174–290 kW | EU | Open in the builder |
| EVAPCO ATWB 10-4N36 closed-circuit cooler (771 tons, 3.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 10-4N36 — an ATWB closed-circuit cooler, 771 nominal tons (3390 kW): rated to cool 1934 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 103.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2543–4238 kW | EU | Open in the builder |
| American Cooling Tower ACX-1042-1 cooling tower (393 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1042-1 — an ACX cooling tower, 393 nominal tons (1726 kW): rated to cool 1182 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 47.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1295–2158 kW | NA | Open in the builder |
| Baltimore Aircoil Nexus NXF-0403N-CS2TT-H3 closed-circuit cooler (60 tons, 263 kW) — modelled Example modelled from published data BAC's NXF-0403N-CS2TT-H3 — a Nexus closed-circuit cooler, 60 nominal tons (263 kW): rated to cool 180 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 11.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 197–329 kW | EU | Open in the builder |
| EVAPCO AT 110-3L18 cooling tower (469 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 110-3L18 — an AT cooling tower, 469 nominal tons (2064 kW): rated to cool 1413 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 53.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1548–2580 kW | EU | Open in the builder |
| American Cooling Tower ACX-1043-1 cooling tower (433 tons, 1.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1043-1 — an ACX cooling tower, 433 nominal tons (1902 kW): rated to cool 1302 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 52.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1426–2377 kW | NA | Open in the builder |
| Baltimore Aircoil PCC-0067-0406N7.5 evaporative condenser (407 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0067-0406N7.5 — a PCC evaporative condenser rejecting 407 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 7.1 m³/s of the maker's own printed air, with a 5.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 305–509 kW | EU | Open in the builder |
| EVAPCO ATWB 10-5I24 closed-circuit cooler (375 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 10-5I24 — an ATWB closed-circuit cooler, 375 nominal tons (1650 kW): rated to cool 942 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 49.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1238–2063 kW | EU | Open in the builder |
| American Cooling Tower ACX-1044-1 cooling tower (461 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1044-1 — an ACX cooling tower, 461 nominal tons (2029 kW): rated to cool 1389 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 55.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1521–2536 kW | NA | Open in the builder |
| Baltimore Aircoil PFI-0406N-3D3EZ-H1 closed-circuit cooler (23 tons, 101 kW) — modelled Example modelled from published data BAC's PFI-0406N-3D3EZ-H1 — a PFi closed-circuit cooler, 23 nominal tons (101 kW): rated to cool 69 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 7.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 76–126 kW | EU | Open in the builder |
| EVAPCO AT 110-3M12 cooling tower (379 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 110-3M12 — an AT cooling tower, 379 nominal tons (1665 kW): rated to cool 1140 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 42.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1249–2081 kW | EU | Open in the builder |
| American Cooling Tower ACX-1045-1 cooling tower (488 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1045-1 — an ACX cooling tower, 488 nominal tons (2147 kW): rated to cool 1470 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 59.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1610–2684 kW | NA | Open in the builder |
| Baltimore Aircoil PT2-0412A-3J cooling tower (157 tons, 692 kW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-0412A-3J — a PT2 cooling tower, 157 nominal tons (692 kW): rated to cool 474 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 519–865 kW | EU | Open in the builder |
| EVAPCO ATWB 10-5I36 closed-circuit cooler (523 tons, 2.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 10-5I36 — an ATWB closed-circuit cooler, 523 nominal tons (2301 kW): rated to cool 1313 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 65.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1726–2876 kW | EU | Open in the builder |
| American Cooling Tower ACX-1046-1 cooling tower (535 tons, 2.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1046-1 — an ACX cooling tower, 535 nominal tons (2353 kW): rated to cool 1611 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 65.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1765–2941 kW | NA | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-07KN cooling tower (308 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-07KN — a Series 1500 cooling tower, 308 nominal tons (1354 kW): rated to cool 927 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 34.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1015–1692 kW | EU | Open in the builder |
| EVAPCO AT 110-3M18 cooling tower (497 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 110-3M18 — an AT cooling tower, 497 nominal tons (2186 kW): rated to cool 1497 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 56.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1640–2733 kW | EU | Open in the builder |
| American Cooling Tower ACX-1047-1 cooling tower (566 tons, 2.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C38C-18R02) ✓ American Cooling Tower's ACX-1047-1 — an ACX cooling tower, 566 nominal tons (2489 kW): rated to cool 1704 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 69.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by American Cooling Tower. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1866–3111 kW | NA | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1020-06N cooling tower (411 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1020-06N — a Series 3000 cooling tower, 411 nominal tons (1805 kW): rated to cool 1236 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 49.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1354–2256 kW | EU | Open in the builder |
| EVAPCO ATWB 10-5J36 closed-circuit cooler (599 tons, 2.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 10-5J36 — an ATWB closed-circuit cooler, 599 nominal tons (2633 kW): rated to cool 1502 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 74.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1975–3291 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers