Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 1,969–1,992 of 3,474

NameCompanyCategoryCapacityMarketsOpen in the builder
EVAPCO AT 215-3I9 cooling tower (357 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-3I9 — an AT cooling tower, 357 nominal tons (1569 kW): rated to cool 1074 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 36.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1176–1961 kWEUOpen in the builder
Baltimore Aircoil VCA-433A evaporative condenser (1.9 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-433A — a VCA evaporative condenser rejecting 1865 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 26.9 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1399–2332 kWEUOpen in the builder
EVAPCO AT 215-3J9 cooling tower (392 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-3J9 — an AT cooling tower, 392 nominal tons (1722 kW): rated to cool 1179 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 41.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1291–2152 kWEUOpen in the builder
Baltimore Aircoil VRC-0538B-1024N-HB evaporative condenser (3.3 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0538B-1024N-HB — a Vertex VRC evaporative condenser rejecting 3264 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 78.7 m³/s of the maker's own printed air, with a 38.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2448–4080 kWEUOpen in the builder
EVAPCO AT 215-4F9 cooling tower (266 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-4F9 — an AT cooling tower, 266 nominal tons (1170 kW): rated to cool 801 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 24.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection877–1462 kWEUOpen in the builder
Baltimore Aircoil CXVB-467-1218-15 evaporative condenser (2.8 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVB-467-1218-15 — a CXVB evaporative condenser rejecting 2829 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 48.6 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2122–3537 kWEUOpen in the builder
EVAPCO AT 215-4G9 cooling tower (318 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-4G9 — an AT cooling tower, 318 nominal tons (1398 kW): rated to cool 957 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1048–1747 kWEUOpen in the builder
Baltimore Aircoil FXV-1212C-32D-M closed-circuit cooler (234 tons, 1.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓
BAC's FXV-1212C-32D-M — an FXV closed-circuit cooler, 234 nominal tons (1030 kW): rated to cool 705 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 40.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection772–1287 kWEUOpen in the builder
EVAPCO AT 215-4H9 cooling tower (345 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-4H9 — an AT cooling tower, 345 nominal tons (1516 kW): rated to cool 1038 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 32.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1137–1895 kWEUOpen in the builder
Baltimore Aircoil PCC-0557-1220N025 evaporative condenser (3.4 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0557-1220N025 — a PCC evaporative condenser rejecting 3384 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 50.0 m³/s of the maker's own printed air, with a 18.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2538–4229 kWEUOpen in the builder
EVAPCO AT 215-4I9 cooling tower (372 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-4I9 — an AT cooling tower, 372 nominal tons (1634 kW): rated to cool 1119 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 35.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1226–2043 kWEUOpen in the builder
Baltimore Aircoil PFI-1012N-3D3DS-N1 closed-circuit cooler (130 tons, 570 kW) — modelled Example modelled from published data
BAC's PFI-1012N-3D3DS-N1 — a PFi closed-circuit cooler, 130 nominal tons (570 kW): rated to cool 390 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 36.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection427–712 kWEUOpen in the builder
EVAPCO AT 215-4J9 cooling tower (413 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-4J9 — an AT cooling tower, 413 nominal tons (1814 kW): rated to cool 1242 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1360–2267 kWEUOpen in the builder
Baltimore Aircoil Series 1500 S15E-1285-06JN cooling tower (157 tons, 692 kW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S15E-1285-06JN — a Series 1500 cooling tower, 157 nominal tons (692 kW): rated to cool 474 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection519–865 kWEUOpen in the builder
EVAPCO AT 217-2G11 cooling tower (315 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 217-2G11 — an AT cooling tower, 315 nominal tons (1385 kW): rated to cool 948 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 38.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1038–1731 kWEUOpen in the builder
Baltimore Aircoil Series 3000 S3E-1424-12S cooling tower (1117 tons, 4.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S3E-1424-12S — a Series 3000 cooling tower, 1117 nominal tons (4912 kW): rated to cool 3363 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 124.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection3684–6139 kWEUOpen in the builder
EVAPCO AT 217-2G9 cooling tower (269 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 217-2G9 — an AT cooling tower, 269 nominal tons (1183 kW): rated to cool 810 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 33.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection887–1479 kWEUOpen in the builder
Baltimore Aircoil Series V VT1-M796-Q cooling tower (793 tons, 3.5 MW) — modelled Example modelled from published data
BAC's VT1-M796-Q — a Series V cooling tower, 793 nominal tons (3488 kW): rated to cool 2388 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 70.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2616–4359 kWEUOpen in the builder
EVAPCO AT 217-2H11 cooling tower (378 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 217-2H11 — an AT cooling tower, 378 nominal tons (1661 kW): rated to cool 1137 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 43.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1245–2076 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-1036N-8D closed-circuit cooler (612 tons, 2.7 MW) — modelled Example modelled from published data
BAC's VF1-1036N-8D — a Series V closed circuit closed-circuit cooler, 612 nominal tons (2690 kW): rated to cool 1842 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 120.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2018–3363 kWEUOpen in the builder
EVAPCO AT 217-2H12 cooling tower (393 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 217-2H12 — an AT cooling tower, 393 nominal tons (1726 kW): rated to cool 1182 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 47.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1295–2158 kWEUOpen in the builder
Baltimore Aircoil VCA-446A evaporative condenser (1.9 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-446A — a VCA evaporative condenser rejecting 1921 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 33.3 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1441–2402 kWEUOpen in the builder
EVAPCO AT 217-2H14 cooling tower (434 tons, 1.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 217-2H14 — an AT cooling tower, 434 nominal tons (1906 kW): rated to cool 1305 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 53.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1429–2382 kWEUOpen in the builder
Baltimore Aircoil VRC-0541B-1224N-HA evaporative condenser (3.3 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0541B-1224N-HA — a Vertex VRC evaporative condenser rejecting 3283 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 56.4 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2462–4104 kWEUOpen in the builder
‹ Previous1…8182838485…145Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers