EVAPCO AT 214-5K52 cooling tower (1964 tons, 8.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 214-5K52 — an AT cooling tower, 1964 nominal tons (8636 kW): rated to cool 5913 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 185.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection6477–10795 kWEUOpen in the builder
Baltimore Aircoil Series V VT1-M742-P cooling tower (740 tons, 3.3 MW) — modelled Example modelled from published data
BAC's VT1-M742-P — a Series V cooling tower, 740 nominal tons (3251 kW): rated to cool 2226 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 66.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2438–4064 kWEUOpen in the builder
EVAPCO AT 214-5L52 cooling tower (2112 tons, 9.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 214-5L52 — an AT cooling tower, 2112 nominal tons (9284 kW): rated to cool 6357 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 199.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection6963–11605 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-1036N-6D closed-circuit cooler (544 tons, 2.4 MW) — modelled Example modelled from published data
BAC's VF1-1036N-6D — a Series V closed circuit closed-circuit cooler, 544 nominal tons (2392 kW): rated to cool 1638 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 122.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1794–2990 kWEUOpen in the builder
EVAPCO AT 214-5M52 cooling tower (2238 tons, 9.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 214-5M52 — an AT cooling tower, 2238 nominal tons (9836 kW): rated to cool 6735 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 210.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection7377–12295 kWEUOpen in the builder
Baltimore Aircoil VCA-429A evaporative condenser (1.8 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-429A — a VCA evaporative condenser rejecting 1848 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 28.3 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1386–2310 kWEUOpen in the builder
EVAPCO AT 214-5N52 cooling tower (2444 tons, 10.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 214-5N52 — an AT cooling tower, 2444 nominal tons (10743 kW): rated to cool 7356 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 230.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection8057–13429 kWEUOpen in the builder
Baltimore Aircoil VRC-0535B-1224N-JA evaporative condenser (3.2 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0535B-1224N-JA — a Vertex VRC evaporative condenser rejecting 3248 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 64.6 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2436–4061 kWEUOpen in the builder
EVAPCO AT 214-5O52 cooling tower (2613 tons, 11.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 214-5O52 — an AT cooling tower, 2613 nominal tons (11488 kW): rated to cool 7866 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 247.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection8616–14360 kWEUOpen in the builder
Baltimore Aircoil CXVB-459-1218-15 evaporative condenser (2.8 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVB-459-1218-15 — a CXVB evaporative condenser rejecting 2781 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 49.0 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2085–3476 kWEUOpen in the builder
EVAPCO AT 215-2F9 cooling tower (216 tons, 951 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-2F9 — an AT cooling tower, 216 nominal tons (951 kW): rated to cool 651 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 25.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection713–1188 kWEUOpen in the builder
Baltimore Aircoil FXV-1212C-30T-P closed-circuit cooler (270 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓
BAC's FXV-1212C-30T-P — an FXV closed-circuit cooler, 270 nominal tons (1187 kW): rated to cool 813 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 51.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection891–1484 kWEUOpen in the builder
EVAPCO AT 215-2G9 cooling tower (273 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-2G9 — an AT cooling tower, 273 nominal tons (1200 kW): rated to cool 822 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 29.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection900–1501 kWEUOpen in the builder
Baltimore Aircoil PCC-0544-2012N040 evaporative condenser (3.3 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0544-2012N040 — a PCC evaporative condenser rejecting 3304 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 66.0 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2478–4130 kWEUOpen in the builder
EVAPCO AT 215-2H9 cooling tower (296 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-2H9 — an AT cooling tower, 296 nominal tons (1301 kW): rated to cool 891 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 33.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection976–1627 kWEUOpen in the builder
Baltimore Aircoil PFI-1012N-3D2ES-O1 closed-circuit cooler (140 tons, 613 kW) — modelled Example modelled from published data
BAC's PFI-1012N-3D2ES-O1 — a PFi closed-circuit cooler, 140 nominal tons (613 kW): rated to cool 420 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 38.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection460–767 kWEUOpen in the builder
EVAPCO AT 215-2I9 cooling tower (318 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-2I9 — an AT cooling tower, 318 nominal tons (1398 kW): rated to cool 957 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 37.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1048–1747 kWEUOpen in the builder
Baltimore Aircoil Series 1500 S15E-1218-12MN-2 cooling tower (1489 tons, 6.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S15E-1218-12MN-2 — a Series 1500 cooling tower, 1489 nominal tons (6546 kW): rated to cool 4482 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 157.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection4909–8182 kWEUOpen in the builder
EVAPCO AT 215-3F9 cooling tower (246 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-3F9 — an AT cooling tower, 246 nominal tons (1082 kW): rated to cool 741 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 24.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection812–1353 kWEUOpen in the builder
Baltimore Aircoil Series 3000 S3E-1424-12R-2 cooling tower (2092 tons, 9.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S3E-1424-12R-2 — a Series 3000 cooling tower, 2092 nominal tons (9197 kW): rated to cool 6297 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 232.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection6897–11496 kWEUOpen in the builder
EVAPCO AT 215-3G9 cooling tower (303 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-3G9 — an AT cooling tower, 303 nominal tons (1332 kW): rated to cool 912 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 29.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection999–1665 kWEUOpen in the builder
Baltimore Aircoil Series V VT1-M758-Q cooling tower (755 tons, 3.3 MW) — modelled Example modelled from published data
BAC's VT1-M758-Q — a Series V cooling tower, 755 nominal tons (3321 kW): rated to cool 2274 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 71.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2491–4151 kWEUOpen in the builder
EVAPCO AT 215-3H9 cooling tower (330 tons, 1.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 215-3H9 — an AT cooling tower, 330 nominal tons (1450 kW): rated to cool 993 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 33.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1088–1813 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-1036N-7D closed-circuit cooler (587 tons, 2.6 MW) — modelled Example modelled from published data
BAC's VF1-1036N-7D — a Series V closed circuit closed-circuit cooler, 587 nominal tons (2581 kW): rated to cool 1767 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 121.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1935–3226 kWEUOpen in the builder