Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 26Systems 3346Components 10248
All categoriesCooling tower / heat rejection 3307VRF / multi-split 8Air handler 7Plant / central 5Fan coil / terminal 4Condensing unit 3Rooftop / packaged 3Split system 3Chiller 2Heat recovery / DOAS 2Evaporative air cooler 1Unit cooler / refrigeration 1
All manufacturersBaltimore Aircoil 1900EVAPCO 1408Midea 2Gree 1Hitachi 1Samsung 1
All seriesAT 992ATWB 416PFi 359PCC 214Series 3000 189Series 1500 173Series V closed circuit 173Vertex VRC 157VCA 151Series V 122CXVB 118FXV 100PT2 46CXVT 40Series V EC 26FXT 20Nexus 12DVM S 1GMV5 1Set Free FSXN 1V4+ 1V6 1
Any capacity500 kW and up 3088100–500 kW 39125–100 kW 76up to 25 kW 25
Any certificationCTI STD-201 (validation C13A-99R28) 822CTI STD-201 (validation C13F-09R12) 416CTI STD-201 (validation C11F-92R20) 362CTI STD-201 (validation C11K-00R03) 153CTI STD-201 (validation C11J-98R12) 100CTI STD-201 (validation C11B-92R07) 90CTI STD-201 (validation C11L-07R05) 46CTI STD-201 (validation C11Q-18R02) 2
All marketsEU 3346
All tagsexample 3346
All suppliersHVAC Builder 3345Aeronim Systems (fictional) 1
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 2233–2256 of 3346

EVAPCO ATWB 10-3N36 closed-circuit cooler (732 tons, 3.2 MW) — modelled

EVAPCO's 10-3N36 — a ATWB closed-circuit cooler, 732 nominal tons (3216 kW): rated to cool 1835 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 106.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2412–4021 kW · EU

EVAPCO ATWB 10-4I12 closed-circuit cooler (169 tons, 744 kW) — modelled

EVAPCO's 10-4I12 — a ATWB closed-circuit cooler, 169 nominal tons (744 kW): rated to cool 425 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 25.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 558–930 kW · EU

EVAPCO ATWB 10-4I36 closed-circuit cooler (488 tons, 2.1 MW) — modelled

EVAPCO's 10-4I36 — a ATWB closed-circuit cooler, 488 nominal tons (2146 kW): rated to cool 1224 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 67.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 1609–2682 kW · EU

EVAPCO ATWB 10-4J12 closed-circuit cooler (195 tons, 857 kW) — modelled

EVAPCO's 10-4J12 — a ATWB closed-circuit cooler, 195 nominal tons (857 kW): rated to cool 489 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 29.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 643–1072 kW · EU

EVAPCO ATWB 10-4J36 closed-circuit cooler (560 tons, 2.5 MW) — modelled

EVAPCO's 10-4J36 — a ATWB closed-circuit cooler, 560 nominal tons (2460 kW): rated to cool 1404 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 76.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 1845–3075 kW · EU

EVAPCO ATWB 10-4K36 closed-circuit cooler (616 tons, 2.7 MW) — modelled

EVAPCO's 10-4K36 — a ATWB closed-circuit cooler, 616 nominal tons (2706 kW): rated to cool 1544 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 84.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2030–3383 kW · EU

EVAPCO ATWB 10-4L36 closed-circuit cooler (662 tons, 2.9 MW) — modelled

EVAPCO's 10-4L36 — a ATWB closed-circuit cooler, 662 nominal tons (2912 kW): rated to cool 1661 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 90.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2184–3640 kW · EU

EVAPCO ATWB 10-4M24 closed-circuit cooler (493 tons, 2.2 MW) — modelled

EVAPCO's 10-4M24 — a ATWB closed-circuit cooler, 493 nominal tons (2169 kW): rated to cool 1238 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 71.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 1627–2711 kW · EU

EVAPCO ATWB 10-4M36 closed-circuit cooler (703 tons, 3.1 MW) — modelled

EVAPCO's 10-4M36 — a ATWB closed-circuit cooler, 703 nominal tons (3090 kW): rated to cool 1763 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 95.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2317–3862 kW · EU

EVAPCO ATWB 10-4N36 closed-circuit cooler (771 tons, 3.4 MW) — modelled

EVAPCO's 10-4N36 — a ATWB closed-circuit cooler, 771 nominal tons (3390 kW): rated to cool 1934 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 103.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2543–4238 kW · EU

EVAPCO ATWB 10-5I24 closed-circuit cooler (375 tons, 1.7 MW) — modelled

EVAPCO's 10-5I24 — a ATWB closed-circuit cooler, 375 nominal tons (1650 kW): rated to cool 942 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 49.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 1238–2063 kW · EU

EVAPCO ATWB 10-5I36 closed-circuit cooler (523 tons, 2.3 MW) — modelled

EVAPCO's 10-5I36 — a ATWB closed-circuit cooler, 523 nominal tons (2301 kW): rated to cool 1313 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 65.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 1726–2876 kW · EU

EVAPCO ATWB 10-5J36 closed-circuit cooler (599 tons, 2.6 MW) — modelled

EVAPCO's 10-5J36 — a ATWB closed-circuit cooler, 599 nominal tons (2633 kW): rated to cool 1502 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 74.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 1975–3291 kW · EU

EVAPCO ATWB 10-5K36 closed-circuit cooler (658 tons, 2.9 MW) — modelled

EVAPCO's 10-5K36 — a ATWB closed-circuit cooler, 658 nominal tons (2892 kW): rated to cool 1650 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 81.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2169–3616 kW · EU

EVAPCO ATWB 10-5L36 closed-circuit cooler (707 tons, 3.1 MW) — modelled

EVAPCO's 10-5L36 — a ATWB closed-circuit cooler, 707 nominal tons (3109 kW): rated to cool 1774 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 88.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2332–3887 kW · EU

EVAPCO ATWB 10-5M36 closed-circuit cooler (750 tons, 3.3 MW) — modelled

EVAPCO's 10-5M36 — a ATWB closed-circuit cooler, 750 nominal tons (3297 kW): rated to cool 1881 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 92.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2473–4121 kW · EU

EVAPCO ATWB 10-5N36 closed-circuit cooler (822 tons, 3.6 MW) — modelled

EVAPCO's 10-5N36 — a ATWB closed-circuit cooler, 822 nominal tons (3614 kW): rated to cool 2062 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 100.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2710–4517 kW · EU

EVAPCO ATWB 10-6I12 closed-circuit cooler (210 tons, 924 kW) — modelled

EVAPCO's 10-6I12 — a ATWB closed-circuit cooler, 210 nominal tons (924 kW): rated to cool 527 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 24.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 693–1155 kW · EU

EVAPCO ATWB 10-6I36 closed-circuit cooler (567 tons, 2.5 MW) — modelled

EVAPCO's 10-6I36 — a ATWB closed-circuit cooler, 567 nominal tons (2491 kW): rated to cool 1422 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 63.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 1868–3114 kW · EU

EVAPCO ATWB 10-6J12 closed-circuit cooler (241 tons, 1.1 MW) — modelled

EVAPCO's 10-6J12 — a ATWB closed-circuit cooler, 241 nominal tons (1058 kW): rated to cool 604 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 27.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 793–1322 kW · EU

EVAPCO ATWB 10-6J36 closed-circuit cooler (647 tons, 2.8 MW) — modelled

EVAPCO's 10-6J36 — a ATWB closed-circuit cooler, 647 nominal tons (2844 kW): rated to cool 1623 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 72.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2133–3555 kW · EU

EVAPCO ATWB 10-6K36 closed-circuit cooler (710 tons, 3.1 MW) — modelled

EVAPCO's 10-6K36 — a ATWB closed-circuit cooler, 710 nominal tons (3121 kW): rated to cool 1781 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 79.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2341–3901 kW · EU

EVAPCO ATWB 10-6L36 closed-circuit cooler (762 tons, 3.4 MW) — modelled

EVAPCO's 10-6L36 — a ATWB closed-circuit cooler, 762 nominal tons (3352 kW): rated to cool 1912 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 85.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2514–4189 kW · EU

EVAPCO ATWB 10-6M36 closed-circuit cooler (808 tons, 3.6 MW) — modelled

EVAPCO's 10-6M36 — a ATWB closed-circuit cooler, 808 nominal tons (3551 kW): rated to cool 2026 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 90.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.

Examplemodelled from published dataCTI STD-201 (validation C13F-09R12) ✓
Cooling tower / heat rejection · 2664–4439 kW · EU
‹ Previous1…9293949596…140Next ›