Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 2,233–2,256 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 224-4P18 cooling tower (1565 tons, 6.9 MW) — modelled Example modelled from published data EVAPCO's 224-4P18 — an AT cooling tower, 1565 nominal tons (6879 kW): rated to cool 4710 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 155.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5159–8598 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-598-1224-20 evaporative condenser (3.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-598-1224-20 — a CXVB evaporative condenser rejecting 3623 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 64.9 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2717–4529 kW | EU | Open in the builder |
| EVAPCO AT 224-4P20 cooling tower (1598 tons, 7.0 MW) — modelled Example modelled from published data EVAPCO's 224-4P20 — an AT cooling tower, 1598 nominal tons (7023 kW): rated to cool 4809 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 157.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5268–8779 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-1218B-36H-O closed-circuit cooler (359 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-1218B-36H-O — an FXV closed-circuit cooler, 359 nominal tons (1577 kW): rated to cool 1080 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 66.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1183–1972 kW | EU | Open in the builder |
| EVAPCO AT 228-2K24 cooling tower (1194 tons, 5.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-2K24 — an AT cooling tower, 1194 nominal tons (5249 kW): rated to cool 3594 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 147.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3937–6561 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0591-1220N040 evaporative condenser (3.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0591-1220N040 — a PCC evaporative condenser rejecting 3590 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 63.8 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2692–4487 kW | EU | Open in the builder |
| EVAPCO AT 228-2L24 cooling tower (1325 tons, 5.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-2L24 — an AT cooling tower, 1325 nominal tons (5823 kW): rated to cool 3987 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 158.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4367–7279 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1012N-5D2DS-N1 closed-circuit cooler (157 tons, 692 kW) — modelled Example modelled from published data BAC's PFI-1012N-5D2DS-N1 — a PFi closed-circuit cooler, 157 nominal tons (692 kW): rated to cool 474 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 34.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 519–865 kW | EU | Open in the builder |
| EVAPCO AT 228-2M24 cooling tower (1397 tons, 6.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-2M24 — an AT cooling tower, 1397 nominal tons (6143 kW): rated to cool 4206 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 167.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4607–7678 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1285-09KN-2 cooling tower (445 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1285-09KN-2 — a Series 1500 cooling tower, 445 nominal tons (1954 kW): rated to cool 1338 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 47.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1466–2443 kW | EU | Open in the builder |
| EVAPCO AT 228-2N24 cooling tower (1515 tons, 6.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-2N24 — an AT cooling tower, 1515 nominal tons (6660 kW): rated to cool 4560 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 184.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4995–8325 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1424-14Q-2 cooling tower (2143 tons, 9.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1424-14Q-2 — a Series 3000 cooling tower, 2143 nominal tons (9420 kW): rated to cool 6450 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 236.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 7065–11775 kW | EU | Open in the builder |
| EVAPCO AT 228-2O24 cooling tower (1628 tons, 7.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-2O24 — an AT cooling tower, 1628 nominal tons (7155 kW): rated to cool 4899 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 197.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5366–8943 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-N418-P cooling tower (417 tons, 1.8 MW) — modelled Example modelled from published data BAC's VT1-N418-P — a Series V cooling tower, 417 nominal tons (1831 kW): rated to cool 1254 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 56.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1374–2289 kW | EU | Open in the builder |
| EVAPCO AT 228-3K24 cooling tower (1371 tons, 6.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-3K24 — an AT cooling tower, 1371 nominal tons (6029 kW): rated to cool 4128 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 145.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4522–7536 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-144N-31P closed-circuit cooler (122 tons, 535 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-144N-31P — a Series V closed circuit closed-circuit cooler, 122 nominal tons (535 kW): rated to cool 366 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 31.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 401–668 kW | EU | Open in the builder |
| EVAPCO AT 228-3L24 cooling tower (1505 tons, 6.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-3L24 — an AT cooling tower, 1505 nominal tons (6616 kW): rated to cool 4530 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 155.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4962–8270 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-537A evaporative condenser (2.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-537A — a VCA evaporative condenser rejecting 2314 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 31.8 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1735–2892 kW | EU | Open in the builder |
| EVAPCO AT 228-3M24 cooling tower (1577 tons, 6.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-3M24 — an AT cooling tower, 1577 nominal tons (6931 kW): rated to cool 4746 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 165.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5199–8664 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0614B-1218N-JB evaporative condenser (3.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0614B-1218N-JB — a Vertex VRC evaporative condenser rejecting 3723 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 59.6 m³/s of the maker's own printed air, with a 40.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2792–4654 kW | EU | Open in the builder |
| EVAPCO AT 228-3N24 cooling tower (1734 tons, 7.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-3N24 — an AT cooling tower, 1734 nominal tons (7624 kW): rated to cool 5220 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 180.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 5718–9530 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-601-1218-45 evaporative condenser (3.6 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-601-1218-45 — a CXVB evaporative condenser rejecting 3641 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 70.1 m³/s of the maker's own printed air, with a 33.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2731–4551 kW | EU | Open in the builder |
| EVAPCO AT 228-3O24 cooling tower (1849 tons, 8.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-3O24 — an AT cooling tower, 1849 nominal tons (8127 kW): rated to cool 5565 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 194.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 6096–10159 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-1218C-16D-M closed-circuit cooler (278 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-1218C-16D-M — an FXV closed-circuit cooler, 278 nominal tons (1222 kW): rated to cool 837 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 63.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 917–1528 kW | EU | Open in the builder |