Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 2,281–2,304 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 228-5O26 cooling tower (2604 tons, 11.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 228-5O26 — an AT cooling tower, 2604 nominal tons (11449 kW): rated to cool 7839 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 246.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 8586–14311 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1285-09LN-2 cooling tower (504 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1285-09LN-2 — a Series 1500 cooling tower, 504 nominal tons (2217 kW): rated to cool 1518 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 53.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1663–2771 kW | EU | Open in the builder |
| EVAPCO AT 26-2F17 cooling tower (178 tons, 784 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-2F17 — an AT cooling tower, 178 nominal tons (784 kW): rated to cool 537 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 588–980 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1424-14R-2 cooling tower (2260 tons, 9.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1424-14R-2 — a Series 3000 cooling tower, 2260 nominal tons (9937 kW): rated to cool 6804 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 249.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 7453–12421 kW | EU | Open in the builder |
| EVAPCO AT 26-2G17 cooling tower (224 tons, 986 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-2G17 — an AT cooling tower, 224 nominal tons (986 kW): rated to cool 675 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 25.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 739–1232 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-N480-P cooling tower (478 tons, 2.1 MW) — modelled Example modelled from published data BAC's VT1-N480-P — a Series V cooling tower, 478 nominal tons (2103 kW): rated to cool 1440 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 54.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1577–2629 kW | EU | Open in the builder |
| EVAPCO AT 26-2H17 cooling tower (246 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-2H17 — an AT cooling tower, 246 nominal tons (1082 kW): rated to cool 741 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 812–1353 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-144N-31R closed-circuit cooler (148 tons, 648 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-144N-31R — a Series V closed circuit closed-circuit cooler, 148 nominal tons (648 kW): rated to cool 444 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 36.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 486–811 kW | EU | Open in the builder |
| EVAPCO AT 26-3F17 cooling tower (202 tons, 889 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-3F17 — an AT cooling tower, 202 nominal tons (889 kW): rated to cool 609 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 667–1112 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-543A evaporative condenser (2.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-543A — a VCA evaporative condenser rejecting 2339 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 52.1 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1754–2924 kW | EU | Open in the builder |
| EVAPCO AT 26-3G17 cooling tower (249 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-3G17 — an AT cooling tower, 249 nominal tons (1095 kW): rated to cool 750 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 24.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 822–1369 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0628B-1224N-HB evaporative condenser (3.8 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0628B-1224N-HB — a Vertex VRC evaporative condenser rejecting 3810 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 80.4 m³/s of the maker's own printed air, with a 38.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2857–4762 kW | EU | Open in the builder |
| EVAPCO AT 26-3H17 cooling tower (276 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-3H17 — an AT cooling tower, 276 nominal tons (1214 kW): rated to cool 831 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 910–1517 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-612-1224-20 evaporative condenser (3.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-612-1224-20 — a CXVB evaporative condenser rejecting 3708 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 65.1 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2781–4635 kW | EU | Open in the builder |
| EVAPCO AT 26-3I17 cooling tower (301 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-3I17 — an AT cooling tower, 301 nominal tons (1323 kW): rated to cool 906 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 30.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 992–1654 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-1218C-20D-K closed-circuit cooler (244 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-1218C-20D-K — an FXV closed-circuit cooler, 244 nominal tons (1073 kW): rated to cool 735 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 50.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 805–1342 kW | EU | Open in the builder |
| EVAPCO AT 26-4F17 cooling tower (218 tons, 960 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-4F17 — an AT cooling tower, 218 nominal tons (960 kW): rated to cool 657 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 20.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 720–1199 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0618-1224N040 evaporative condenser (3.8 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0618-1224N040 — a PCC evaporative condenser rejecting 3754 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 72.1 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2815–4692 kW | EU | Open in the builder |
| EVAPCO AT 26-4G17 cooling tower (261 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-4G17 — an AT cooling tower, 261 nominal tons (1148 kW): rated to cool 786 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 24.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 861–1435 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-1024N-2D2DS-J2 closed-circuit cooler (150 tons, 657 kW) — modelled Example modelled from published data BAC's PFI-1024N-2D2DS-J2 — a PFi closed-circuit cooler, 150 nominal tons (657 kW): rated to cool 450 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 54.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 493–822 kW | EU | Open in the builder |
| EVAPCO AT 26-4H17 cooling tower (286 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-4H17 — an AT cooling tower, 286 nominal tons (1257 kW): rated to cool 861 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 27.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 943–1572 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1285-09MN cooling tower (275 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1285-09MN — a Series 1500 cooling tower, 275 nominal tons (1209 kW): rated to cool 828 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 29.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 907–1512 kW | EU | Open in the builder |
| EVAPCO AT 26-4I17 cooling tower (314 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 26-4I17 — an AT cooling tower, 314 nominal tons (1380 kW): rated to cool 945 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 30.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1035–1725 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1424-14S cooling tower (1211 tons, 5.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1424-14S — a Series 3000 cooling tower, 1211 nominal tons (5323 kW): rated to cool 3645 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 132.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3993–6654 kW | EU | Open in the builder |