Published systems

Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 2,329–2,352 of 3,474

NameCompanyCategoryCapacityMarketsOpen in the builder
EVAPCO AT 27-2K28 cooling tower (593 tons, 2.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-2K28 — an AT cooling tower, 593 nominal tons (2607 kW): rated to cool 1785 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 66.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1955–3259 kWEUOpen in the builder
Baltimore Aircoil VCA-580A evaporative condenser (2.5 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-580A — a VCA evaporative condenser rejecting 2499 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 42.3 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1874–3123 kWEUOpen in the builder
EVAPCO AT 27-2L28 cooling tower (470 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-2L28 — an AT cooling tower, 470 nominal tons (2068 kW): rated to cool 1416 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 70.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1551–2585 kWEUOpen in the builder
Baltimore Aircoil VRC-0636B-1218N-LA evaporative condenser (3.9 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0636B-1218N-LA — a Vertex VRC evaporative condenser rejecting 3856 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 54.3 m³/s of the maker's own printed air, with a 33.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2892–4820 kWEUOpen in the builder
EVAPCO AT 27-3G36 cooling tower (509 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3G36 — an AT cooling tower, 509 nominal tons (2239 kW): rated to cool 1533 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 61.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1679–2799 kWEUOpen in the builder
Baltimore Aircoil CXVB-629-1224-30 evaporative condenser (3.8 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's CXVB-629-1224-30 — a CXVB evaporative condenser rejecting 3811 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 75.4 m³/s of the maker's own printed air, with a 22.4 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2858–4764 kWEUOpen in the builder
EVAPCO AT 27-3H24 cooling tower (362 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3H24 — an AT cooling tower, 362 nominal tons (1590 kW): rated to cool 1089 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 42.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1193–1988 kWEUOpen in the builder
Baltimore Aircoil FXV-1218C-24Q-P closed-circuit cooler (387 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓
BAC's FXV-1218C-24Q-P — an FXV closed-circuit cooler, 387 nominal tons (1700 kW): rated to cool 1164 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 78.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1275–2125 kWEUOpen in the builder
EVAPCO AT 27-3H28 cooling tower (381 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3H28 — an AT cooling tower, 381 nominal tons (1674 kW): rated to cool 1146 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 47.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1255–2092 kWEUOpen in the builder
Baltimore Aircoil PCC-0622-1220N040 evaporative condenser (3.8 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's PCC-0622-1220N040 — a PCC evaporative condenser rejecting 3778 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 57.6 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2834–4723 kWEUOpen in the builder
EVAPCO AT 27-3H36 cooling tower (598 tons, 2.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3H36 — an AT cooling tower, 598 nominal tons (2629 kW): rated to cool 1800 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 70.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1972–3286 kWEUOpen in the builder
Baltimore Aircoil PFI-1024N-2D4ES-K2 closed-circuit cooler (175 tons, 771 kW) — modelled Example modelled from published data
BAC's PFI-1024N-2D4ES-K2 — a PFi closed-circuit cooler, 175 nominal tons (771 kW): rated to cool 528 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 54.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection578–964 kWEUOpen in the builder
EVAPCO AT 27-3I24 cooling tower (401 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3I24 — an AT cooling tower, 401 nominal tons (1761 kW): rated to cool 1206 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 46.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1321–2202 kWEUOpen in the builder
Baltimore Aircoil Series 1500 S15E-1285-10LN cooling tower (263 tons, 1.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S15E-1285-10LN — a Series 1500 cooling tower, 263 nominal tons (1157 kW): rated to cool 792 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 28.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection868–1446 kWEUOpen in the builder
EVAPCO AT 27-3I28 cooling tower (524 tons, 2.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3I28 — an AT cooling tower, 524 nominal tons (2305 kW): rated to cool 1578 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 52.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1728–2881 kWEUOpen in the builder
Baltimore Aircoil Series 3000 S3E-1424-14T cooling tower (1299 tons, 5.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓
BAC's S3E-1424-14T — a Series 3000 cooling tower, 1299 nominal tons (5709 kW): rated to cool 3909 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 141.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection4282–7136 kWEUOpen in the builder
EVAPCO AT 27-3I36 cooling tower (662 tons, 2.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3I36 — an AT cooling tower, 662 nominal tons (2909 kW): rated to cool 1992 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 76.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2182–3637 kWEUOpen in the builder
Baltimore Aircoil Series V VTL-021-F cooling tower (21 tons, 92 kW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓
BAC's VTL-021-F — a Series V cooling tower, 21 nominal tons (92 kW): rated to cool 63 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 3.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection69–115 kWEUOpen in the builder
EVAPCO AT 27-3J24 cooling tower (461 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3J24 — an AT cooling tower, 461 nominal tons (2029 kW): rated to cool 1389 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 53.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1521–2536 kWEUOpen in the builder
Baltimore Aircoil Series V closed circuit VF1-144N-41R closed-circuit cooler (156 tons, 688 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓
BAC's VF1-144N-41R — a Series V closed circuit closed-circuit cooler, 156 nominal tons (688 kW): rated to cool 471 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 35.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection516–860 kWEUOpen in the builder
EVAPCO AT 27-3J28 cooling tower (496 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3J28 — an AT cooling tower, 496 nominal tons (2182 kW): rated to cool 1494 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 59.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection1636–2727 kWEUOpen in the builder
Baltimore Aircoil VCA-581A evaporative condenser (2.5 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VCA-581A — a VCA evaporative condenser rejecting 2503 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 48.4 m³/s of the maker's own printed air, with a 16.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection1877–3129 kWEUOpen in the builder
EVAPCO AT 27-3J36 cooling tower (760 tons, 3.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓
EVAPCO's 27-3J36 — an AT cooling tower, 760 nominal tons (3343 kW): rated to cool 2289 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 87.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model.
HVAC BuilderCooling tower / heat rejection2507–4179 kWEUOpen in the builder
Baltimore Aircoil VRC-0641B-1224N-KA evaporative condenser (3.9 MW rejection) — modelled Example modelled from published data
Baltimore Aircoil's VRC-0641B-1224N-KA — a Vertex VRC evaporative condenser rejecting 3886 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 69.0 m³/s of the maker's own printed air, with a 29.8 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection.
HVAC BuilderCooling tower / heat rejection2915–4858 kWEUOpen in the builder
‹ Previous1…96979899100…145Next ›

Publishing here

Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers