Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 697–720 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 14-3E9 cooling tower (86 tons, 377 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 14-3E9 — an AT cooling tower, 86 nominal tons (377 kW): rated to cool 258 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 9.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 283–471 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-1866-2826-100 evaporative condenser (11.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-1866-2826-100 — a CXVT evaporative condenser rejecting 11335 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 200.7 m³/s of the maker's own printed air, with a 74.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 8501–14169 kW | EU | Open in the builder |
| EVAPCO ATWB 14-6J9 closed-circuit cooler (329 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 14-6J9 — an ATWB closed-circuit cooler, 329 nominal tons (1447 kW): rated to cool 826 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 36.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1085–1809 kW | EU | Open in the builder |
| Baltimore Aircoil FXT-0712C-L cooling tower (239 tons, 1.1 MW) — modelled Example modelled from published data BAC's FXT-0712C-L — an FXT cooling tower, 239 nominal tons (1052 kW): rated to cool 720 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 30.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 789–1314 kW | EU | Open in the builder |
| EVAPCO AT 14-3F12 cooling tower (129 tons, 565 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 14-3F12 — an AT cooling tower, 129 nominal tons (565 kW): rated to cool 387 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 14.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 424–706 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0809B-24T-M closed-circuit cooler (119 tons, 521 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0809B-24T-M — an FXV closed-circuit cooler, 119 nominal tons (521 kW): rated to cool 357 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 26.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 391–652 kW | EU | Open in the builder |
| EVAPCO ATWB 14-7J18 closed-circuit cooler (733 tons, 3.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 14-7J18 — an ATWB closed-circuit cooler, 733 nominal tons (3222 kW): rated to cool 1839 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 70.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2417–4028 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0177-0718N010 evaporative condenser (1.1 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0177-0718N010 — a PCC evaporative condenser rejecting 1075 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 31.7 m³/s of the maker's own printed air, with a 7.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 806–1344 kW | EU | Open in the builder |
| EVAPCO AT 14-3F4 cooling tower (43 tons, 188 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 14-3F4 — an AT cooling tower, 43 nominal tons (188 kW): rated to cool 129 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 5.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 141–235 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0412N-5D3EZ-G2 closed-circuit cooler (59 tons, 259 kW) — modelled Example modelled from published data BAC's PFI-0412N-5D3EZ-G2 — a PFi closed-circuit cooler, 59 nominal tons (259 kW): rated to cool 177 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 10.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 194–323 kW | EU | Open in the builder |
| EVAPCO ATWB 14-7J9 closed-circuit cooler (379 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 14-7J9 — an ATWB closed-circuit cooler, 379 nominal tons (1666 kW): rated to cool 950 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 35.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1249–2082 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-0812A-5O cooling tower (379 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-0812A-5O — a PT2 cooling tower, 379 nominal tons (1665 kW): rated to cool 1140 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 35.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1249–2081 kW | EU | Open in the builder |
| EVAPCO AT 14-3F6 cooling tower (64 tons, 280 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 14-3F6 — an AT cooling tower, 64 nominal tons (280 kW): rated to cool 192 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 7.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 210–351 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-10LN cooling tower (420 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-10LN — a Series 1500 cooling tower, 420 nominal tons (1845 kW): rated to cool 1263 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 44.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1383–2306 kW | EU | Open in the builder |
| EVAPCO ATWB 17-3I14 closed-circuit cooler (323 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 17-3I14 — an ATWB closed-circuit cooler, 323 nominal tons (1420 kW): rated to cool 810 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 52.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1065–1774 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-06O cooling tower (498 tons, 2.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-06O — a Series 3000 cooling tower, 498 nominal tons (2191 kW): rated to cool 1500 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 60.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1643–2738 kW | EU | Open in the builder |
| EVAPCO AT 14-3F9 cooling tower (100 tons, 438 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 14-3F9 — an AT cooling tower, 100 nominal tons (438 kW): rated to cool 300 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 11.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 329–548 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT0-78-K cooling tower (78 tons, 342 kW) — modelled Example modelled from published data CTI STD-201 (validation C11B-92R07) ✓ BAC's VT0-78-K — a Series V cooling tower, 78 nominal tons (342 kW): rated to cool 234 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 8.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 256–427 kW | EU | Open in the builder |
| EVAPCO ATWB 17-3J14 closed-circuit cooler (372 tons, 1.6 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 17-3J14 — an ATWB closed-circuit cooler, 372 nominal tons (1633 kW): rated to cool 932 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 60.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1225–2041 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-027-22J closed-circuit cooler (28 tons, 123 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-027-22J — a Series V closed circuit closed-circuit cooler, 28 nominal tons (123 kW): rated to cool 84 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 7.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 92–153 kW | EU | Open in the builder |
| EVAPCO AT 14-3G12 cooling tower (150 tons, 657 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 14-3G12 — an AT cooling tower, 150 nominal tons (657 kW): rated to cool 450 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 16.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 493–822 kW | EU | Open in the builder |
| Baltimore Aircoil VCL-167 evaporative condenser (719 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCL-167 — a Series V EC evaporative condenser rejecting 719 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 17.4 m³/s of the maker's own printed air, with a 7.5 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 540–899 kW | EU | Open in the builder |
| EVAPCO ATWB 17-3K14 closed-circuit cooler (410 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 17-3K14 — an ATWB closed-circuit cooler, 410 nominal tons (1801 kW): rated to cool 1028 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 65.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1351–2251 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-1240A evaporative condenser (5.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-1240A — a VCA evaporative condenser rejecting 5342 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 94.9 m³/s of the maker's own printed air, with a 44.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 4007–6678 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers