Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 793–816 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 17-3G18 cooling tower (260 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3G18 — an AT cooling tower, 260 nominal tons (1144 kW): rated to cool 783 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 30.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 858–1429 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-1125-P cooling tower (1121 tons, 4.9 MW) — modelled Example modelled from published data BAC's VT1-1125-P — a Series V cooling tower, 1121 nominal tons (4929 kW): rated to cool 3375 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 112.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3697–6161 kW | EU | Open in the builder |
| EVAPCO ATWB 17-7K14 closed-circuit cooler (578 tons, 2.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 17-7K14 — an ATWB closed-circuit cooler, 578 nominal tons (2542 kW): rated to cool 1450 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 58.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1906–3177 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-027-32J closed-circuit cooler (31 tons, 136 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-027-32J — a Series V closed circuit closed-circuit cooler, 31 nominal tons (136 kW): rated to cool 93 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 7.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 102–170 kW | EU | Open in the builder |
| EVAPCO AT 17-3G9 cooling tower (129 tons, 565 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3G9 — an AT cooling tower, 129 nominal tons (565 kW): rated to cool 387 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 14.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 424–706 kW | EU | Open in the builder |
| Baltimore Aircoil VCL-234 evaporative condenser (1.0 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCL-234 — a Series V EC evaporative condenser rejecting 1008 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 20.5 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 756–1260 kW | EU | Open in the builder |
| EVAPCO ATWB 17-7L14 closed-circuit cooler (620 tons, 2.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 17-7L14 — an ATWB closed-circuit cooler, 620 nominal tons (2727 kW): rated to cool 1556 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 61.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2045–3408 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-1284A evaporative condenser (5.5 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-1284A — a VCA evaporative condenser rejecting 5532 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 94.0 m³/s of the maker's own printed air, with a 33.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 4149–6915 kW | EU | Open in the builder |
| EVAPCO AT 17-3H12 cooling tower (183 tons, 806 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3H12 — an AT cooling tower, 183 nominal tons (806 kW): rated to cool 552 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 605–1008 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0327B-1018N-HA evaporative condenser (2.0 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0327B-1018N-HA — a Vertex VRC evaporative condenser rejecting 1982 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 41.4 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1486–2477 kW | EU | Open in the builder |
| EVAPCO ATWB 17-7M14 closed-circuit cooler (657 tons, 2.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 17-7M14 — an ATWB closed-circuit cooler, 657 nominal tons (2887 kW): rated to cool 1647 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 65.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2165–3609 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-152-0809-5 evaporative condenser (921 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-152-0809-5 — a CXVB evaporative condenser rejecting 921 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 16.8 m³/s of the maker's own printed air, with a 3.7 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 691–1151 kW | EU | Open in the builder |
| EVAPCO AT 17-3H14 cooling tower (193 tons, 850 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3H14 — an AT cooling tower, 193 nominal tons (850 kW): rated to cool 582 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 23.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 637–1062 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-617-1224-15 evaporative condenser (3.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-617-1224-15 — a CXVT evaporative condenser rejecting 3746 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 61.6 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 2810–4683 kW | EU | Open in the builder |
| EVAPCO ATWB 20-3I18 closed-circuit cooler (461 tons, 2.0 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-3I18 — an ATWB closed-circuit cooler, 461 nominal tons (2025 kW): rated to cool 1155 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 69.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1519–2531 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0809B-36D-M closed-circuit cooler (145 tons, 635 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0809B-36D-M — an FXV closed-circuit cooler, 145 nominal tons (635 kW): rated to cool 435 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 26.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 476–794 kW | EU | Open in the builder |
| EVAPCO AT 17-3H18 cooling tower (305 tons, 1.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3H18 — an AT cooling tower, 305 nominal tons (1341 kW): rated to cool 918 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 34.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1006–1676 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0222-0718N015 evaporative condenser (1.3 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0222-0718N015 — a PCC evaporative condenser rejecting 1348 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 34.1 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1011–1686 kW | EU | Open in the builder |
| EVAPCO ATWB 20-3I36 closed-circuit cooler (876 tons, 3.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-3I36 — an ATWB closed-circuit cooler, 876 nominal tons (3853 kW): rated to cool 2198 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 138.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2890–4816 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-3D1DS-H1 closed-circuit cooler (50 tons, 219 kW) — modelled Example modelled from published data BAC's PFI-0709N-3D1DS-H1 — a PFi closed-circuit cooler, 50 nominal tons (219 kW): rated to cool 150 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 15.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 164–274 kW | EU | Open in the builder |
| EVAPCO AT 17-3H9 cooling tower (151 tons, 666 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3H9 — an AT cooling tower, 151 nominal tons (666 kW): rated to cool 456 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 17.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 499–832 kW | EU | Open in the builder |
| Baltimore Aircoil PT2-0814A-4O cooling tower (410 tons, 1.8 MW) — modelled Example modelled from published data CTI STD-201 (validation C11L-07R05) ✓ BAC's PT2-0814A-4O — a PT2 cooling tower, 410 nominal tons (1801 kW): rated to cool 1233 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 40.2 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1351–2251 kW | EU | Open in the builder |
| EVAPCO ATWB 20-3J18 closed-circuit cooler (529 tons, 2.3 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-3J18 — an ATWB closed-circuit cooler, 529 nominal tons (2326 kW): rated to cool 1327 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 79.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1744–2907 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-11KN cooling tower (386 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-11KN — a Series 1500 cooling tower, 386 nominal tons (1696 kW): rated to cool 1161 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 41.3 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1272–2119 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers