Published systems
Complete machines published by their suppliers — each with a public spec page whose design-point performance is solved live from the actual model, not copied from a brochure. Open one in the builder to run it against your own climate, or request a quote right here.
Showing 841–864 of 3,474
| Name | Company | Category | Capacity | Markets | Open in the builder |
|---|---|---|---|---|---|
| EVAPCO AT 17-3J18 cooling tower (388 tons, 1.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3J18 — an AT cooling tower, 388 nominal tons (1704 kW): rated to cool 1167 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 42.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1278–2130 kW | EU | Open in the builder |
| Baltimore Aircoil Series 1500 S15E-1212-11KN-2 cooling tower (771 tons, 3.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S15E-1212-11KN-2 — a Series 1500 cooling tower, 771 nominal tons (3391 kW): rated to cool 2322 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 82.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2543–4239 kW | EU | Open in the builder |
| EVAPCO ATWB 20-3N18 closed-circuit cooler (732 tons, 3.2 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-3N18 — an ATWB closed-circuit cooler, 732 nominal tons (3216 kW): rated to cool 1835 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 106.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2412–4021 kW | EU | Open in the builder |
| Baltimore Aircoil Series 3000 S3E-1222-07O-2 cooling tower (1105 tons, 4.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C11F-92R20) ✓ BAC's S3E-1222-07O-2 — a Series 3000 cooling tower, 1105 nominal tons (4859 kW): rated to cool 3327 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 129.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3644–6074 kW | EU | Open in the builder |
| EVAPCO AT 17-3J9 cooling tower (192 tons, 846 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3J9 — an AT cooling tower, 192 nominal tons (846 kW): rated to cool 579 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 21.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 634–1057 kW | EU | Open in the builder |
| Baltimore Aircoil Series V VT1-1245-R cooling tower (1241 tons, 5.5 MW) — modelled Example modelled from published data BAC's VT1-1245-R — a Series V cooling tower, 1241 nominal tons (5455 kW): rated to cool 3735 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 127.8 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 4091–6819 kW | EU | Open in the builder |
| EVAPCO ATWB 20-4I18 closed-circuit cooler (488 tons, 2.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-4I18 — an ATWB closed-circuit cooler, 488 nominal tons (2146 kW): rated to cool 1224 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 67.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1609–2682 kW | EU | Open in the builder |
| Baltimore Aircoil Series V closed circuit VF1-027-42H closed-circuit cooler (28 tons, 123 kW) — modelled Example modelled from published data CTI STD-201 (validation C11K-00R03) ✓ BAC's VF1-027-42H — a Series V closed circuit closed-circuit cooler, 28 nominal tons (123 kW): rated to cool 84 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 6.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with a forced-draft fan on the leaving air, where its nameplate cannot be counted twice against a certified point. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 92–153 kW | EU | Open in the builder |
| EVAPCO AT 17-3K12 cooling tower (257 tons, 1.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3K12 — an AT cooling tower, 257 nominal tons (1130 kW): rated to cool 774 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 29.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 848–1413 kW | EU | Open in the builder |
| Baltimore Aircoil VCL-271 evaporative condenser (1.2 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCL-271 — a Series V EC evaporative condenser rejecting 1168 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 22.4 m³/s of the maker's own printed air, with a 14.9 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 876–1460 kW | EU | Open in the builder |
| EVAPCO ATWB 20-4I36 closed-circuit cooler (929 tons, 4.1 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-4I36 — an ATWB closed-circuit cooler, 929 nominal tons (4086 kW): rated to cool 2331 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 134.0 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3064–5107 kW | EU | Open in the builder |
| Baltimore Aircoil VCA-1321A evaporative condenser (5.7 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VCA-1321A — a VCA evaporative condenser rejecting 5691 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 86.7 m³/s of the maker's own printed air, with a 74.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 4268–7114 kW | EU | Open in the builder |
| EVAPCO AT 17-3K14 cooling tower (320 tons, 1.4 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3K14 — an AT cooling tower, 320 nominal tons (1406 kW): rated to cool 963 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 31.9 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1055–1758 kW | EU | Open in the builder |
| Baltimore Aircoil VRC-0332B-1012N-JB evaporative condenser (2.0 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's VRC-0332B-1012N-JB — a Vertex VRC evaporative condenser rejecting 2016 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 41.3 m³/s of the maker's own printed air, with a 30.0 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1512–2520 kW | EU | Open in the builder |
| EVAPCO ATWB 20-4J18 closed-circuit cooler (560 tons, 2.5 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-4J18 — an ATWB closed-circuit cooler, 560 nominal tons (2460 kW): rated to cool 1404 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 76.7 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1845–3075 kW | EU | Open in the builder |
| Baltimore Aircoil CXVB-163-0809-7.5 evaporative condenser (988 kW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVB-163-0809-7.5 — a CXVB evaporative condenser rejecting 988 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 19.4 m³/s of the maker's own printed air, with a 5.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 741–1235 kW | EU | Open in the builder |
| EVAPCO AT 17-3K18 cooling tower (429 tons, 1.9 MW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3K18 — an AT cooling tower, 429 nominal tons (1884 kW): rated to cool 1290 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 46.6 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 1413–2355 kW | EU | Open in the builder |
| Baltimore Aircoil CXVT-676-1224-25 evaporative condenser (4.1 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's CXVT-676-1224-25 — a CXVT evaporative condenser rejecting 4107 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 73.0 m³/s of the maker's own printed air, with a 18.6 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 3080–5134 kW | EU | Open in the builder |
| EVAPCO ATWB 20-4J36 closed-circuit cooler (1067 tons, 4.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-4J36 — an ATWB closed-circuit cooler, 1067 nominal tons (4689 kW): rated to cool 2675 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 153.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 3516–5861 kW | EU | Open in the builder |
| Baltimore Aircoil FXV-0812A-12D-M closed-circuit cooler (108 tons, 473 kW) — modelled Example modelled from published data CTI STD-201 (validation C11J-98R12) ✓ BAC's FXV-0812A-12D-M — an FXV closed-circuit cooler, 108 nominal tons (473 kW): rated to cool 324 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 31.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 355–591 kW | EU | Open in the builder |
| EVAPCO AT 17-3K9 cooling tower (212 tons, 933 kW) — modelled Example modelled from published data CTI STD-201 (validation C13A-99R28) ✓ EVAPCO's 17-3K9 — an AT cooling tower, 212 nominal tons (933 kW): rated to cool 639 USGPM of water from 95 to 85 °F at a 78 °F entering wet bulb on 23.1 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. Open fill: the water meets the air directly — Braun's enthalpy-basis tower model. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving water exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 700–1167 kW | EU | Open in the builder |
| Baltimore Aircoil PCC-0233-1012N015 evaporative condenser (1.4 MW rejection) — modelled Example modelled from published data Baltimore Aircoil's PCC-0233-1012N015 — a PCC evaporative condenser rejecting 1415 kW at a 40.6 °C condensing temperature and a 25.6 °C entering wet bulb, on 30.9 m³/s of the maker's own printed air, with a 11.2 kW fan. The heat comes from outside the drawing, because that is what this machine is: heat rejection, and the plant that sends it the heat is the customer's. Given exactly the rejection BAC certify, the model solves the condensing temperature the machine settles at — which is the reading, and the only figure here that is ours rather than theirs. The rating condition is an inference and the listing says so: BAC's sheets never define the condition of their Base Heat Rejection. | HVAC Builder | Cooling tower / heat rejection | 1061–1769 kW | EU | Open in the builder |
| EVAPCO ATWB 20-4K18 closed-circuit cooler (616 tons, 2.7 MW) — modelled Example modelled from published data CTI STD-201 (validation C13F-09R12) ✓ EVAPCO's 20-4K18 — an ATWB closed-circuit cooler, 616 nominal tons (2706 kW): rated to cool 1544 USGPM of process fluid from 102 to 90 °F at a 75 °F entering wet bulb on 84.4 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by EVAPCO. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 2030–3383 kW | EU | Open in the builder |
| Baltimore Aircoil PFI-0709N-3D1ES-J1 closed-circuit cooler (58 tons, 254 kW) — modelled Example modelled from published data BAC's PFI-0709N-3D1ES-J1 — a PFi closed-circuit cooler, 58 nominal tons (254 kW): rated to cool 174 USGPM of process fluid from 95 to 85 °F at a 78 °F entering wet bulb on 16.5 m³/s of air, the maker's own printed airflow, and drawn at those flows with an induced-draft fan on the leaving air, pulling through the fill. The process fluid runs inside a coil under the spray — the evaporative wet-coil model, its two conductances split as the range's own coil volumes say. The model derives the machine's NTU from that one certified point, so it reproduces the rated leaving process fluid exactly and predicts nothing else — one point per model is an input, not a validation. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model. | HVAC Builder | Cooling tower / heat rejection | 191–318 kW | EU | Open in the builder |
Publishing here
Suppliers publish from the builder's supplier portal — free to register, free to publish. How it works for system suppliers